E910.72A61DC ELMOS Semiconductor, E910.72A61DC Datasheet - Page 16

no-image

E910.72A61DC

Manufacturer Part Number
E910.72A61DC
Description
Motor / Motion / Ignition Controllers & Drivers 6x HVAC motor driver/pulse count
Manufacturer
ELMOS Semiconductor
Type
DC Motor 6x Half Bridger
Datasheet

Specifications of E910.72A61DC

Rohs
yes
Product
Brushed DC Motor Drivers
Operating Supply Voltage
5 V
Supply Current
3 mA
Operating Temperature
- 40 C to + 85 C
Mounting Style
SMD/SMT
Package / Case
QFN-32
Number Of Outputs
5
Output Current
100 mA
Output Voltage
6 V to 19 V
Power Dissipation
1 W
6) Address 000
5.2.3 Data telegram supervision
If the result of any of the parity checks is incorrect the complete telegram is ignored, and DRB gets activated.
The clock input CLK is checked during CSB low time for a minimum frequency of 1 kHz. In case the frequency is
lower, the data is ignored and DRB gets activated. For supervision in standby mode, the oscillator is switched on
after a falling edge on CSB and the supervision gets started. The first detection period is prolonged by the settling
time of internal references, which causes a start up time of the oscillator in the range of a few 100μs.
Short pulses of CSB without any SPI clock CLK are not interpreted as invalid data, DRB does not go low. During the
short pulse, the internal oscillator is switched on. If CSB goes high, the oscillator is switched off and the IC stays in
standby mode.
address Correlation
address bits
DC Motor 6 x Half briDgE witH ripplE CoUnt
aDVanCE proDUCt inforMation - MaY 05, 2011
ELMOS Semiconductor AG
bit no.
35
36
37
001
001
010
010
011
011
100
100
110
110
111
111
101
101
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
can be used to read data back from TXD without changing the state of any output or to wake up the IC.
MotorSel[0]
MotorSel[1]
switchstop bit selection bit = 0
bit name
Parity
0
1
0
1
0
1
0
1
0
1
0
1
0
1
b
b
b
b
b
b
b
b
b
b
b
b
b
b
6)
Description
MSB of motor controller select bits
00
01
10
11
LSB of motor controller select bits
Odd parity of third byte
Content 00000000
Control)
OUT1_HV = Low
OUT1_HV = High
OUT2_HV = Low
OUT2_HV = High
OUT3_HV = Low
OUT3_HV = High
OUT4_HV = Low
OUT4_HV = High
OUT5_HV = Low
OUT5_HV = High
OUT6_HV = Low
OUT6_HV = High
Standby mode
Software reset
b
b
b
b
: Configuration data valid for motor control register no.1
: Configuration data valid for motor control register no.2
: Configuration data valid for motor control register no.3
: Configuration data valid for all motor control registers
b
(Direct Half bridge
Data Sheet
b
16/34
or 11111111
b
leads to parity error
selection bit = 1
Motor 1 (OUT1_HV - OUT2_HV)
Stop motor 1
Motor 2 (OUT3_HV - OUT4_HV)
Stop motor 2
Motor 3 (OUT5_HV - OUT6_HV)
Stop motor 3
Motor 4 (OUT2_HV - OUT3_HV)
Stop motor 4
Motor 5 (OUT4_HV - OUT5_HV)
Stop motor 5
Configuration register no.1
Invalid address, no reaction
Configuration register no.2
Software reset
QM-No.: 25DS0057E.00
b
(Motor Control)
E910.72

Related parts for E910.72A61DC