TJA1022T,118 NXP Semiconductors, TJA1022T,118 Datasheet - Page 8

no-image

TJA1022T,118

Manufacturer Part Number
TJA1022T,118
Description
LIN Transceivers DUAL LIN 5-18V
Manufacturer
NXP Semiconductors
Datasheet

Specifications of TJA1022T,118

Rohs
yes
Operating Supply Voltage
5 V to 18 V
Supply Current
10 mA
Package / Case
SO-14
Mounting Style
SMD/SMT
Factory Pack Quantity
2500
NXP Semiconductors
TJA1022
Product data sheet
7.3.1 Remote wake-up via the LIN bus
7.3.2 Wake-up via SLPx_N
7.3 Transceiver wake-up
7.4 Operation during automotive cranking pulses
7.5 Operation when supply voltage is outside specified operating range
A falling edge on pin LINx followed by a LOW level maintained for t
a rising edge on pin LINx triggers a remote wake-up (see
the time period t
Sleep mode irrespective of the status of pin TXDx.
If SLPx_N is held HIGH for t
Normal mode.
TJA1022 remains fully operational during automotive cranking pulses because the LIN
transceivers are fully specified down to V
If V
cannot be guaranteed to remain within the operating ranges specified in
Table
In Normal mode:
Fig 4.
BAT
If the input level on pin TXDx is HIGH, the LIN transmitter output on pin LINx will be
recessive.
If the input level on pin LINx is recessive, the receiver output on pin RXDx will be
HIGH.
If the voltage on pin V
LIN network pull-up resistance should be greater than 680  and the total LIN network
capacitance should be less than 6.8 nF to ensure reliable LIN data transfer.
If the voltage on pin V
the active LIN transmit path(s) is interrupted and both LIN outputs will be recessive.
The previously active LIN transmit path(s) is switched on again when V
above V
8.
> 18 V or V
Remote wake-up behavior
V
LINx
th(VBATL)H
All information provided in this document is subject to legal disclaimers.
wake(dom)LIN
LIN dominant
V
BAT
BUSdom
sleep mode
and the associated TXDx pin is HIGH.
< 5 V, the TJA1022 may remain operational, but parameter values
Rev. 1 — 30 March 2012
BAT
BAT
is measured either in Normal mode while TXDx is HIGH, or in
gotonorm
LIN recessive
drops below the LOW-level V
rises to 27 V (e.g. during an automotive jump-start), the total
t
wake(dom)LIN
, the transceiver will switch from Sleep mode to
BAT
= 5 V.
Dual LIN 2.2/SAE J2602 transceiver
Figure
BAT
LOW threshold, V
4). It should be noted that
wake(dom)LIN
standby mode
TJA1022
© NXP B.V. 2012. All rights reserved.
015aaa297
Table 7
V
ground
BUSrec
BAT
followed by
rises
th(VBATL)L
and
8 of 26
,

Related parts for TJA1022T,118