MAX3107EVKIT+ Maxim Integrated, MAX3107EVKIT+ Datasheet - Page 35

no-image

MAX3107EVKIT+

Manufacturer Part Number
MAX3107EVKIT+
Description
UART Interface IC UART with integrated Oscillator
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX3107EVKIT+

Number Of Channels
1
Data Rate
24 Mbps
Supply Voltage - Max
3.6 V
Supply Voltage - Min
1.71 V
Supply Current
4 mA
Maxim Integrated
IrDA Register
The IrDA allows selection of IrDA SIR and MIR-compliant pulse shaping at the TX and RX interfaces. It also allows
inversion of the TX and RX logic, independently of whether IrDA is enabled or not.
Bits 7 and 6: No Function
Bit 5: TxInv
Set the TxInv bit high to invert the logic at the TX output. This is independent of IrDA operation.
Bit 4: RxInv
Set the RxInv bit high to invert the logic state at the RX input. This is independent of IrDA operation.
Bit 3: MIR
Set the MIR and IrDAEn bits high to select IrDA 1.1 (MIR) with 1/4 period pulse widths.
Bit 2: No Function
Bit 2 must be kept logic 0.
Bit 1: SIR
Set the SIR bit and the IrDAEn bits high to select IrDA 1.0 pulses (SIR) with 3/16th period pulses.
Bit 0: IrDAEn
Set the IrDAEn bit high so that IrDA-compliant pulses are produced at the TX output and the MAX3107 receiver expects
such pulses at its Rx input. If IrDAEn is set to low (default), normal (nonIrDA) pulses are generated and expected at
the receiver. IrDAEn must be used in conjunction with the SIR or MIR select bits.
FlowLvl is used for selecting the RxFIFO threshold levels used for software (XON/XOFF) and hardware (RTS/CTS) flow control.
FlowLvl—Flow Level Register
Bits 7–4: Resume[7:4]
Resume[7:4] sets the transmit FIFO threshold at which an XON is automatically sent or RTS/CLKOUT is automati-
cally set low. This signals the far-end station to start transmission. The actual threshold level is calculated as 8 times
Resume[7:4]. The resulting level is in the range of 0 to 120.
Bits 3–0: Halt[3:0]
Halt[3:0] sets a receive FIFO threshold level at which an XOFF is automatically sent or RTS/CLKOUT is automatically set
high, depending on whether auto software or hardware flow control is enabled. This signals the far-end station to halt
transmission. The actual threshold level is calculated as 8 times Halt[3:0]. Hence, the selectable threshold granularity
is eight. The resulting level is in the range of 0 to 120.
ADDRESS:
MODE:
ADDRESS:
MODE:
RESET
RESET
NAME
NAME
BIT
BIT
Resume3
7
0
7
0
0x0E
R/W
0x0F
R/W
Resume2
SPI/I
6
0
6
0
Resume1
2
TxInv
5
0
5
0
C UART with 128-Word FIFOs
Resume0
RxInv
4
0
4
0
Halt3
MIR
3
0
3
0
Halt2
2
0
2
0
MAX3107
Halt1
SIR
1
0
1
0
IrDAEn
Halt0
0
0
0
0
35