EDS6-120 FUJI [Fuji Electric], EDS6-120 Datasheet - Page 11

no-image

EDS6-120

Manufacturer Part Number
EDS6-120
Description
E SERIESE ELECTROMAGNETIC FLOWMETER(SEPARATE TYPE)
Manufacturer
FUJI [Fuji Electric]
Datasheet
If you want the instrument with certain parameters factory set as you desire, specify them in the following parameter designation
tables 1 and 2.
<Parameter designation table 1>
Range
Instantaneous
output
low-cut point
Total
direction
Total constant
(Note 2)
(Total value
per pulse)
Total pulse
width
(Note 3)
Filter
Measured fluid :
Setting item
Damping
LCD
1st line
indication
LCD
2nd line
indication
Company :
Name :
Standard set value
5.0s
Real scale
indication
Unit: m
Total real scale
indication
Unit: m
By table-1
(Note 5)
0.0%
FORWARD
/REVERSE (Note4)
1m
30ms
off
3
(Note 1)
3
3
/h
1.0 to 99.0s
<1st line, 2nd line>
q Real scale indication
w Arbitrary real scale unit
e Percent indication (%)
r Total real scale indication
t Arbitrary total real scale unit
y TAG No. indication
u Bar graph indication
i Non-display
0.5 to 10 m/s
converted to flow velocity.
0.0% to 10.0%
FORWARD
FORWARD/REVERSE
Value: 0.001 to 1000
Unit : mL, L, m
0.1 to 2000ms
on
off
Volume unit: mL, L, m
Mass unit: g, kg
Time unit: /s, /min, /h
• Unit factor: 0.00001 to
• Unit name: Arbitrary value
Volume unit: mL, L, m
Mass unit: g, kg
• Unit factor: 0.00001 to
• Unit name: Arbitrary value
(Percent indication can also
be indicated simultaneously
in 1% step)
Range
3
9999999
of 4 characters
9999999
of 4 charactes
3
3
Put check marks into
<Designation of 1st line indication>
Select an item from the following.
<Designation of 2nd line indication>
Select an item from the following.
Volume unit:
Time unit:
None.
Volume unit:
None.
Real scale indication
Arbitrary real scale indication
Percent indication
Total real scale indication
Arbitrary total real scale
indication
TAG No. indication
Bar graph indication
Non-display
Real scale indication
Arbitrary real scale indication
Percent indication
Total real scale indication
Arbitrary total real scale
indication
TAG No. indication
Bar graph indication
Non-display
FORWARD
FORWARD/REVERSE
mL,
on
off
Item to select
L,
Telephone No. :
/s,
mL,
/h,
m
3
/min,
/d
L,
Sector :
which precede items to modify for.
m
3
According to selection of left item,
designate necessary item and value.
Volume unit:
Mass unit:
Time unit:
Unit factor: 0.00001 to
*Value converted the units into L
Unit name:
None.
Volume unit:
Mass unit:
Unit factor: 0.00001 to
*Value converted the units into L
Unit name:
None
None
None
According to selection of left item,
designate necessary item and value.
Volume unit:
Mass unit:
Time unit:
Unit factor: 0.00001 to
*Value converted the units into L
Unit name:
None.
Volume unit:
Mass unit:
Unit factor: 0.00001 to
*Value converted the units into L
Unit name:
None
None
None
Must be designated in 4 significant digits.
Value:
None.
Value:
None.
.
.
value designation
Item selection or
.
%
[ms]
9999999
9999999
9999999
9999999
[s]
g,
g,
g,
g,
/s,
/s,
mL,
mL,
mL,
mL,
kg
kg
kg
kg
/min,
/min,
L,
L,
L,
L,
/h
/h
m
m
m
m
3
3
3
3
Example
100.0
3.5%
50.0[ms]
020.0s
1000000
1000000
1000000
1000000
t/h
t/h
t
t
11