LUCL9313AP-D AGERE [Agere Systems], LUCL9313AP-D Datasheet - Page 19

no-image

LUCL9313AP-D

Manufacturer Part Number
LUCL9313AP-D
Description
Line Interface and Line Access Circuit Full-Feature SLIC and Ringing for TR-57 Applications
Manufacturer
AGERE [Agere Systems]
Datasheet
September 2001
Agere Systems Inc.
Electrical Characteristics
Logic Inputs and Outputs, V
Table 9. Logic Inputs and Outputs
Timing Requirements
Table 10. Timing Requirements
Data control is via a parallel latched data control scheme. Data latches are edge-level sensitive. Data is latched in
when the LATCH control input goes low. Data must be set up t
LATCH goes high. While LATCH is low, the user should not change the data control inputs at B0, B1, and B2. The
data control inputs at B0, B1, and B2 may only be changed when LATCH is high. NSTAT supervision output is not
controlled by the LATCH control input.
Input Voltages:
Input Current:
Output Voltages (CMOS):
Minimum Setup Time from B0, B1, B2 to LATCH
Minimum Hold Time from LATCH to B0, B1, B2
Low Level
High Level
Low Level (V
High Level (V
Low Level (V
High Level (V
DD
DD
DD
DD
= 5.25 V, V
= 4.75 V, I
= 5.25 V, V
= 4.75 V, I
Parameter
OL
Parameter
OH
I
I
= 0.4 V)
LATCH
B0, B1,
B2, B3
= 2.4 V)
= 180 A)
= –20 A)
DD
(continued)
Full-Feature SLIC and Ringing Relay for TR-57 Applications
= 5.0 V
Figure 3. Timing Requirements
t
SU
Symbol
SU
t
t
SU
HL
ns before LATCH goes low and held t
Symbol
t
HL
Min
200
V
V
V
V
50
I
I
IH
OH
IL
OL
IH
IL
–0.5
Typ
Min
2.0
2.4
0
Typ
0.4
2.4
0.2
Max
Max
V
±50
±50
V
0.7
0.4
DD
CC
HL
ns after
Unit
ns
ns
12-3526(F)
Unit
V
V
V
V
A
A
19

Related parts for LUCL9313AP-D