Electrical Characteristics
SLIC Two-Wire Port
Table 6. SLIC Two-Wire Port
* Guarantees 46 dB from 300 Hz to 3.4 kHz, with 50 , 1% protection, resistors into a complex resistive termination impedance.
16
PT and PR Drive Current = dc + Longitudinal + Signal Currents
Signal Current
Longitudinal Current Capability per Wire (longitudinal current is indepen-
dc Active Mode Loop Current – I
dc Current-limit Variation:
Loop Resistance Range (from PT/PR) (3.17 dBm overload into 600
V
Offset at V
dc Feed Resistance (includes internal SLIC dc resistance and break
dV/dT Sensitivity at PT/PR
Ground Start State PT Resistance
Powerup Open Loop Voltages (V
Powerup Open Loop Voltages:
Loop Closure Threshold:
Loop Closure Threshold Hysteresis
Ground Start:
Longitudinal to Metallic Balance at PT/PR*
Metallic to Longitudinal (harm) Balance:
dent of dc loop current)
switch resistance)
(Test Method: IEEE
REF
Programming Range
Voltage at V
V
I
Forward/Reverse Active Mode PT – PR – V
Voltage at OVH (programming voltage)
Forward/Reverse Active Mode PT – PR – V
Common Mode
Scan Mode PT – PR – V
Voltage at LCTH
Gain ICM to RGDET
Common-mode Detector Threshold
200 Hz to 3.4 kHz
200 Hz to 4000 Hz
LOOP
PROG
= 20 mA at V
= 0.8 V (I
PROG
PROG
LIMIT
BAT1
= 40 mA)
Std. 455):
= –48 V
BAT1
Parameter
LIM
BAT1
(continued)
(R
= –48 V):
LOOP
= 100 ):
BAT1
BAT1
(programming range)
(OVH to GND)
):
1900
2.23
Min
–40
100
8.5
0.2
5.5
5.5
75
10
10
50
61
40
0
0
0
5
(V
BAT1
2.35
Typ
200
6.1
15
75
20
0
5
1
+ 1)/2
September 2001
Agere Systems Inc.
V
Max
2.47
13.5
100
0.9
1.9
45
40
15
10
REF
mApeak
mArms
mArms
Unit
V/ s
A/mA
mA
mV
mA
k
dB
dB
%
%
V
V
V
V
V
V
V
V