GS-BT2416C1AT1 STMICROELECTRONICS [STMicroelectronics], GS-BT2416C1AT1 Datasheet - Page 30

no-image

GS-BT2416C1AT1

Manufacturer Part Number
GS-BT2416C1AT1
Description
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet
AT command
A.26
A.27
A.28
30/38
AT+UARTSETUP
Set the local UART settings. The changes take affect immediately after the OK response. It
is advisable to issue an AT command after the AT+UARTSETUP in order to make sure the
MCU is synchronized up correctly with the new settings. The new settings are used both for
the COMMAND MODE and DATA MODE. Use the command AT+BTMACROSTART to store
a startup setting for the UART. Is not allowed to use AT+UARTSETUP command in a macro!
Due to internal time needed to write a flash memory area a little time delay is possible
before any return value.
AT+UARTSETUP=?
Output the current UART configuration settings. The command generates an +UARTSETUP
message with the configuration parameters of the module’s UART. For the parameters list,
see the AT+UARTSETUP command.
AT+VER
Requests the ID, version number and revision date of the firmware. The command
generates a +VER event.
Syntax: AT+UARTSETUP=BaudRate, DataBits, Parity, Stopbits, Fc
Parameters:
Baud Rate: UART baud rate in bps. Possible values are: 300, 1200, 2400, 4800,
9600 (default), 19200, 38400, 57600, 115200, 153600, 230400, 460800.
DataBits: possible values are 5, 6, 7, 8 (default)
Parity: possible values are None (default), Even, Odd
StopBits: possible values are 1 (default), 2
Fc: flow control. Possible values are None (default), Hardware
Return value: <OK, ERROR>
Syntax: AT+UARTSETUP=?
Return value: +UARTSETUP, <OK, ERROR>
Syntax: AT+VER
Return value: +VER, <OK, ERROR>
GS-BT2416C1.AT1

Related parts for GS-BT2416C1AT1