ZL50075GAC ZARLINK [Zarlink Semiconductor Inc], ZL50075GAC Datasheet - Page 17

no-image

ZL50075GAC

Manufacturer Part Number
ZL50075GAC
Description
32 K Channel Digital Switch with High Jitter Tolerance, Rate Conversion per Group of 2 Streams (8, 16, 32 or 64 Mbps), and 64 Inputs and 64 Outputs
Manufacturer
ZARLINK [Zarlink Semiconductor Inc]
Datasheet
When the internal system clock is not used as the clock source, there are limitations to the data rate and the output
clock rate. For all the input and output stream groups that do not use the internal system clock as their clock source,
the data rate is limited to be no higher than the selected clock source’s rate (e.g., if CKi0 runs at 16.384 MHz and it
is selected as the clock source for input stream group 3, then the maximum data rate of STiA3 and STiB3 is
16.384 Mbps). Similarly, for all the output clocks that do not use the internal system clock as their clock source, the
clock rate is limited to be no higher than the selected clock source’s rate (e.g., if CKi0 runs at 32.768 MHz and it is
selected as the clock source for output clock CKo0, then the maximum clock rate of CKo0 is 32.768 MHz).
3.0
There are two output timing pairs, CKo1 - 0 and FPo1 - 0. By default these signals generate ST-BUS, negative
timing, and use the internal system clock as reference clock source. Their default clock rates are 65.536 MHz for
CKo0 and 32.768 MHz for CKo1. Their properties can also be individually programmed in the Output Clock Control
Register (OCCR) to control the frame pulse format (ST-BUS/GCI-Bus), frame pulse polarity, clock polarity, clock
rate (8.192 MHz, 16.384 MHz, 32.768 MHz or 65.536 MHz), and reference clock source. Refer to Section 14.6 for
programming details. Note that the reference clock source can be set to either the internal system clock or the input
CKi0 and FPi0 signals. If the input CKi0 and FPi0 is selected as the reference source, the output clock cannot be
programmed to generate a higher clock frequency than the reference source. As each output timing pair has its
own bit settings, they can be set to provide different output timings. For 65.536 MHz output clock, the total
loading on the output should not be larger than 10pF.
4.0
To be able to interface with external buffers, the output signals can be set to enter a high impedance or drive high
state on a per-channel basis. The Per Channel Function (bits 31 - 29) in the Connection Memory Bits can be set to
001 to drive the channel output high, or to 000, 110 or 111 to set the channel into a high impedance state.
5.0
The Group Control Registers (GCR) are used to adjust the input delay and output advancement for each input and
output data groups. Each group is independently programmed.
5.1
The input sampling point delay programming feature provides users with the flexibility of handling different wire
delays when incoming traffic is from different sources.
By default, all input streams have zero delay, such that bit 7 is the first bit that appears after the input frame
boundary (assuming ST-BUS formatting). The nominal input sampling point with zero delay is at the 3/4 bit time.
The input delay is enabled by the Input Sample Point Delay (bit 8 - 4) in the Group Control Registers 0 - 31 (GCR0
- 31) as described in Section 14.4 on page 39. The input sampling point delay can range from 0 to 7 3/4 bit delay
with a 1/4 bit resolution on a per group basis.
Input Sampling Point Delay Programming
Output Clock (CKo) and Output Frame Pulse (FPo) Timing
Output Channel Control
Data Input Delay and Data Output Advancement
Zarlink Semiconductor Inc.
ZL50075
17
Data Sheet