If a change to the range register is required during a sequence, it
is necessary to first stop the sequence by writing to the control
register and setting Seq1 to 0 and Seq2 to 0. Next, the write to
the range register should be completed to change the required
range. The previously selected sequence should then be initiated
again by writing to the control register and setting Seq1 to 0 and
Seq2 to 1. The ADC converts on the first channel in the
sequence.
The AD7324 can be configured to convert a sequence of
consecutive channels (see Figure 45). This sequence begins by
converting on Channel 0 and ends with a final channel as
selected by Bit ADD1 to Bit ADD0 in the control register. In
this configuration, there is no need for a write to the sequence
register. To operate the AD7324 in this mode, set Seq1 to 1 and
Seq2 to 0 in the control register, and then select the final channel
in the sequence by programming Bit ADD1 to Bit ADD0 in the
control register.
CS
CS
CS
CS
DIN: WRITE BIT = 0 OR DIN LINE HELD LOW TO CONTINUE TO
DIN: WRITE TO CONTROL REGISTER TO SELECT THE FINAL
DIN: WRITE TO RANGE REGISTER TO SELECT THE RANGE
CHANNEL IN THE CONSECUTIVE SEQUENCE, SET Seq1 = 1
AND Seq2 = 0. SELECT OUTPUT CODING FOR SEQUENCE.
DIN: WRITE BIT = 0 OR DIN LINE HELD LOW TO CONTINUE
CS
DOUT: CONVERSION RESULT FROM CHANNEL 0, ± 10V
THROUGH SEQUENCE OF CONSECUTIVE CHANNELS.
DOUT: CONVERSION RESULT FROM CHANNEL 1,
DOUT: CONVERSION RESULT FROM CHANNEL 0,
DOUT: CONVERSION RESULT FROM CHANNEL 0,
RANGE SELECTED IN RANGE REGISTER,
CONVERT THROUGH THE SEQUENCE OF
RANGE SELECTED IN RANGE REGISTER.
RANGE SELECTED IN RANGE REGISTER.
Figure 45. Flowchart for Consecutive Sequence of Channels
FOR ANALOG INPUT CHANNELS.
FROM CHANNEL IN SEQUENCE.
RANGE, SINGLE-ENDED MODE.
SEQUENCE, Seq1 = 0, Seq2 = 0.
DOUT: CONVERSION RESULT
CONSECUTIVE CHANNELS.
DIN: WRITE TO CONTROL
REGISTER TO STOP THE
SINGLE-ENDED MODE.
A SEQUENCE.
POWER ON.
STOPPING
Rev. 0 | Page 27 of 36
Once the control register is configured to operate the AD7324
in this mode, the DIN line can be held low, or the write bit can
be set to 0. To return to traditional multichannel operation, a
write to the control register to set Seq1 to 0 and Seq2 to 0 is
necessary.
When the Seq1 and Seq2 are both set to 0, or when both are set
to 1, the AD7324 is configured to operate in traditional multi-
channel mode, where a write to Channel Address Bit ADD1 to
Bit ADD0 in the control register selects the next channel for
conversion.
ON CONSECUTIVE SEQUENCE
CONTINUOUSLY CONVERT
OF CHANNELS.
DIN TIED LOW/WRITE BIT = 0.
AD7324