M24512 STMicroelectronics, M24512 Datasheet - Page 8

no-image

M24512

Manufacturer Part Number
M24512
Description
512 Kbit Serial IC Bus EEPROM
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24512-DFMC6TG
Manufacturer:
AD
Quantity:
9 240
Company:
Part Number:
M24512-DFMC6TG
Quantity:
297
Company:
Part Number:
M24512-DFMC6TG
Quantity:
40
Part Number:
M24512-DFMN6TP
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M24512-DFMN6TP
Quantity:
50 000
Company:
Part Number:
M24512-DFMN6TP
Quantity:
5 000
Part Number:
M24512-HRMN6TP
Manufacturer:
MICRON
Quantity:
26
Part Number:
M24512-RDW6TP
Manufacturer:
SAMSUNG
Quantity:
10 940
Part Number:
M24512-RDW6TP
Manufacturer:
ST
0
Part Number:
M24512-RDW6TP
Manufacturer:
ST
Quantity:
150
Part Number:
M24512-RDW6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24512-RDW6TP
0
Part Number:
M24512-RMC6TG
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M24512-RMC6TG
Quantity:
15 000
Part Number:
M24512-RMN6TP
Manufacturer:
MICRON
Quantity:
15 000
Part Number:
M24512-RMN6TP
Quantity:
20 000
Part Number:
M24512-RMN6TP
Manufacturer:
ST
Quantity:
256
Part Number:
M24512-RMN6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24512-RMN6TP
0
M24512
Figure 7. Write Cycle Polling Flowchart using ACK
internal address counter. The counter is then in-
cremented. The master terminates the transfer
with a STOP condition, as shown in Figure 8, with-
out acknowledging the byte output.
Sequential Read
This mode can be initiated with either a Current
Address Read or a Random Address Read. The
master does acknowledge the data byte output in
this case, and the memory continues to output the
next byte in sequence. To terminate the stream of
bytes, the master must not acknowledge the last
byte output, and must generate a STOP condition.
The output data comes from consecutive address-
es, with the internal address counter automatically
incremented after each byte output. After the last
memory address, the address counter ‘rolls-over’
and the memory continues to output data from
memory address 00h.
8/16
First byte of instruction
with RW = 0 already
decoded by M24xxx
ReSTART
STOP
NO
NO
DEVICE SELECT
START Condition
WRITE Cycle
Addressing the
with RW = 0
Operation is
in Progress
Returned
Memory
ACK
Next
YES
WRITE Operation
Proceed
YES
Acknowledge in Read Mode
In all read modes, the memory waits, after each
byte read, for an acknowledgment during the 9
bit time. If the master does not pull the SDA line
low during this time, the memory terminates the
data transfer and switches to its stand-by state.
Byte Address
Send
Random Address
READ Operation
Proceed
AI01847
th

Related parts for M24512