For a practical meter, not only voltage and current amplitudes, but also phase angles and harmonic content
may change constantly. Thus, simple RMS measurements are inherently inaccurate. A modern solid-state
71M6541D/F/G and 71M6542F/G Data Sheet
3
3.1
The energy delivered by a power source into a load can be expressed as:
Assuming phase angles are constant, the following formulae apply:
electricity meter IC such as the Teridian 71M654x functions by emulating the integral operation above,
i.e., it processes current and voltage samples through an ADC at a constant frequency. As long as the
ADC resolution is high enough and the sample frequency is beyond the harmonic range of interest, the
current and voltage samples, multiplied with the time period of sampling yield an accurate quantity for the
momentary energy. Summing up the momentary energy quantities over time results in very accurate
results for accumulated energy.
Figure 28
50 samples of the voltage and current signals over a period of 20 ms. The application of 240 VAC and
100 A results in an accumulation of 480 Ws (= 0.133 Wh) over the 20 ms period, as indicated by the
accumulated power curve. The described sampling method works reliably, even in the presence of dynamic
phase shift and harmonic distortion.
Functional Description
Theory of Operation
shows the shapes of V(t), I(t), the momentary power and the accumulated power, resulting from
P = Real Energy [Wh] = V * A * cos φ* t
Q = Reactive Energy [VARh] = V * A * sin φ * t
S = Apparent Energy [VAh] =
-100
-200
-300
-400
-500
500
400
300
200
100
Figure 28: Voltage, Current, Momentary and Accumulated Energy
0
0
Current [A]
Voltage [V]
Energy per Interval [Ws]
Accumulated Energy [Ws]
5
E
P +
2
=
Q
0
t
V
2
10
(
t
)
I
(
t
)
dt
15
20