S29PL-J SPANSION [SPANSION], S29PL-J Datasheet - Page 64

no-image

S29PL-J

Manufacturer Part Number
S29PL-J
Description
CMOS 3.0 Volt-only, Simultaneous-Read/Write Flash Memory with Enhanced VersatileIO Control
Manufacturer
SPANSION [SPANSION]
Datasheet
62
Legend
BA = Address of bank switching to autoselect mode, bypass mode, or erase operation. Determined by PL127J: Amax:A20, PL064J and
PA = Program Address (Amax:A0). Addresses latch on falling edge of WE# or CE# (CE1#/CE2# for PL129J) pulse, whichever happens later.
PD = Program Data (DQ15:DQ0) written to location PA. Data latches on rising edge of WE# or CE# (CE1#/CE2# for PL129J) pulse,
RA = Read Address (Amax:A0).
RD = Read Data (DQ15:DQ0) from location RA.
SA = Sector Address (Amax:A12) for verifying (in autoselect mode) or erasing.
WD = Write Data. See “Configuration Register” definition for specific write data. Data latched on rising edge of WE#.
X = Don’t care
Notes
1. See
2. All values are in hexadecimal.
3. Shaded cells in table denote read cycles. All other cycles are write operations.
4. During unlock and command cycles, when lower address bits are 555 or 2AAh as shown in table, address bits higher than A11 (except
5. No unlock or command cycles required when bank is reading array data.
6. The Reset command is required to return to reading array (or to erase-suspend-read mode if previously in Erase Suspend) when bank is
7. Fourth cycle of autoselect command sequence is a read cycle. System must provide bank address to obtain manufacturer ID or device ID
8. The data is DQ6=1 for factory and customer locked and DQ7=1 for factory locked.
9. The data is 00h for an unprotected sector group and 01h for a protected sector group.
10. Device ID must be read across cycles 4, 5, and 6. PL127J (X0Eh = 2220h, X0Fh = 2200h), PL129J (X0Eh = 2221h, X0Fh =
11. System may read and program in non-erasing sectors, or enter autoselect mode, when in Program/Erase Suspend mode. Program/
12. Program/Erase Resume command is valid only during Erase Suspend mode, and requires bank address.
13. Command is valid when device is ready to read array data or when device is in autoselect mode.
14. WP#/ACC must be at V
15. Unlock Bypass Entry command is required prior to any Unlock Bypass operation. Unlock Bypass Reset command is required to return to
Command (Notes)
Read
Reset
Program
Chip Erase
Sector Erase
Program/Erase Suspend
Program/Erase Resume
CFI Query
Accelerated Program
Unlock Bypass Entry
Unlock Bypass Program
Unlock Bypass Erase
Unlock Bypass CFI
Unlock Bypass Reset
where BA is required) and data bits higher than DQ7 are don’t cares.
in autoselect mode, or if DQ5 goes high (while bank is providing status information).
information. See
2200h),PL064J (X0Eh = 2202h, X0Fh = 2201h), PL032J (X0Eh = 220Ah, X0Fh = 2201h).
Erase Suspend command is valid only during a sector erase operation, and requires bank address.
the reading array.
PL129J: Amax:A19, PL032J: Amax:A18.
whichever happens first.
(5)
(6)
Manufacturer ID
Device ID
Secured Silicon Sector
Factory Protect
Sector Group
Protect
Table 10.1 on page 20
(13)
Verify(9)
(10)
Autoselect Command Sequence on page 56
(13)(15)
(15)
(15)
(15)
(15)
(8)
(12)
(15)
(11)
ID
during the entire operation of command.
D a t a
for description of bus operations.
1
1
4
6
4
4
4
6
6
1
1
1
2
3
2
2
1
2
Table 15.1 Memory Array Command Definitions
Addr
XXX
XXX
555
555
555
555
555
555
555
555
RA
BA
BA
XX
XX
XX
XX
55
S h e e t
Data
AAA
RD
AA
AA
AA
AA
AA
AA
B0
A0
AA
A0
F0
30
98
80
98
90
S29PL-J
Addr
XXX
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
PA
XX
PA
( A d v a n c e
Data
for more information.
PD
PD
55
55
55
55
55
55
55
55
10
00
Addr
(BA)
(BA)
(BA)
(BA)
555
555
555
555
555
555
555
555
Bus Cycles (Notes 1–4)
Data
90
90
90
90
A0
80
80
20
I n f o r m a t i o n )
(SA) X02
Addr
(BA)
(BA)
X00
X01
X03
555
555
PA
S29PL-J_00_A9 September 22, 2006
XX00/
XX01
227E
Data
PD
AA
AA
(8)
01
Addr
(BA)
X0E
2AA
2AA
Data
(10)
55
55
Addr
(BA)
X0F
555
SA
Data
(10)
10
30

Related parts for S29PL-J