LTC4110EUHF LINER [Linear Technology], LTC4110EUHF Datasheet - Page 22

no-image

LTC4110EUHF

Manufacturer Part Number
LTC4110EUHF
Description
Battery Backup System Manager
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC4110EUHF
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC4110EUHF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC4110EUHF#PBF
Manufacturer:
NEC
Quantity:
1 686
LTC4110
OPERATION
system load not be adequate to absorb the current. The
primary protection is accomplished with an external current
sense resistor (R
pins, through which the system load current fl ows. When
the voltage across the resistor reaches 10mV (I
less, representing a low forward current, calibration mode
is terminated. The current protection can be completely
disabled by connecting both CLP and CLN pins to GND.
As an alternative where R
the application, a secondary method is accomplished by
monitoring the supply voltage through the DCDIV pin.
Once the DCDIV pin voltage goes above V
mode is terminated. In either case, the CAL_FLT register is
set high and the charge mode is automatically entered to
begin recharging the battery. Both of these protections are
automatically disabled when not in calibration. However,
in calibration, one or the other of these two protective
methods should be used. You can optionally do both.
Failure to implement any form of protection can result in
destructive voltages being generated in the application.
If the calibration cycle fails due to loss of the main power
source a fault condition results that sets the CAL_FLT
register bit and backup mode is entered.
An optional external thermistor network is sampled at
regular intervals to monitor battery temperature and to
detect battery presence. If the thermistor value indicates
a temperature outside of ideal limits (hot or over-range)
the calibration current is halted and the CAL_FLT bit will
be set high. When the thermistor value returns to an ac-
ceptable value (under-range, cold or ideal), charge mode
is automatically entered to begin recharging the battery.
Calibration can be restarted by clearing the CAL_FLT bit
and sending another CAL_START command.
An open thermistor (over-range) indicates absence of a
battery. To defeat the temperature monitoring function, re-
place the thermistor with a resistor to indicate ideal battery
temperature. When a thermistor is not used, the resistor
circuit must be routed through the battery connector if
battery presence detection is required. If the battery should
be removed during calibration, calibration will terminate
and the CAL_FLT read bit will be set high.
22
CL
), connected between the CLP and CLN
CL
sensing is not an option for
OVP
, calibration
BDT
) or
The CAL_FLT bit can be cleared by writing a one to the
CAL_RESET or POR_RESET registers, or by forcing the
SHDN pin high. The CAL_FLT bit is not cleared by remov-
ing and reapplying the supply input if the battery has
maintained suffi cient voltage (V
Calibration can start only if the CAL_FLT bit in the
BBuStatus() register is clear. Once the LTC4110 is in cali-
bration state, the following events will stop calibration:
• BKDRV is sensed. The CAL_FLT bit is set.
• A HOT thermistor is sensed. The CAL_FLT bit is set.
• Loss of battery presence is sensed. The CAL_FLT bit is
• The calibration cutoff threshold has been reached.
• An OVER_TEMP_ALARM, RESERVED_ALARM, or
• Loss of AC presence. The CAL_FLT bit is set.
SHUTDOWN MODE
The LTC4110 can be forced into either a micropower
shutdown state or an all logic register reset state with
the SHDN pin.
DCIN
set.
The CAL_COMPLETE bit is set. The LTC4110 will start
charging based upon the TYPE and SELA pins.
TERMINATE_DISCHARGE_ALARM bit in the Alarm-
Warning() register is set. The CAL_FLT bit is set. The
LTC4110 will start charging.
CURRENT FLOW
SYSTEM LOAD
Figure 6. Calibration Mode Operation
INID
ON
LTC4110
BACKUP LOAD
CHGFET
DCHFET
BATID
OFF
BAT
OFF
≥ 2.7V).
4110 F06
BATTERY
4110fa

Related parts for LTC4110EUHF