SC16C754 Philips Semiconductors, SC16C754 Datasheet - Page 24

no-image

SC16C754

Manufacturer Part Number
SC16C754
Description
Quad UART with 64-byte FIFO
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C754BIA68
Manufacturer:
PHI-Pbf
Quantity:
216
Part Number:
SC16C754BIA68
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C754BIA68,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C754BIA68,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C754BIA68,518
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C754BIA68,529
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C754BIB80
Manufacturer:
NXP Semiconductors
Quantity:
1 780
Part Number:
SC16C754BIB80
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C754BIB80,528
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C754BIBM
Manufacturer:
NXP
Quantity:
1 432
Part Number:
SC16C754BIBM
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C754IA68
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Philips Semiconductors
9397 750 11618
Product data
7.4 Line control register (LCR)
This register controls the data communication format. The word length, number of
stop bits, and parity type are selected by writing the appropriate bits to the LCR.
Table 12
Table 12:
Bit
7
6
5
4
3
2
1-0
Symbol
LCR[7]
LCR[6]
LCR[5]
LCR[4]
LCR[3]
LCR[2]
LCR[1-0]
shows the line control register bit settings.
Line Control Register bits description
Rev. 04 — 19 June 2003
Description
Divisor latch enable.
Break control bit. When enabled, the Break control bit causes a break
condition to be transmitted (the TX output is forced to a logic 0 state).
This condition exists until disabled by setting LCR[6] to a logic 0.
Set parity. LCR[5] selects the forced parity format (if LCR[3] = 1).
Parity type select.
Parity enable.
Number of Stop bits. Specifies the number of stop bits.
Word length bits 1, 0. These two bits specify the word length to be
transmitted or received.
Logic 0 = Divisor latch disabled (normal default condition).
Logic 1 = Divisor latch enabled.
Logic 0 = no TX break condition (normal default condition).
Logic 1 = forces the transmitter output (TX) to a logic 0 to alert the
communication terminal to a line break condition.
Logic 0 = parity is not forced (normal default condition).
LCR[5] = logic 1 and LCR[4] = logic 0: parity bit is forced to a logical 1
for the transmit and receive data.
LCR[5] = logic 1 and LCR[4] = logic 1: parity bit is forced to a logical 0
for the transmit and receive data.
Logic 0 = ODD Parity is generated (if LCR[3] = 1).
Logic 1 = EVEN Parity is generated (if LCR[3] = 1).
Logic 0 = no parity (normal default condition).
Logic 1 = a parity bit is generated during transmission and the
receiver checks for received parity.
0 = 1 stop bit (word length = 5, 6, 7, 8)
1 = 1.5 stop bits (word length = 5)
1 = 2 stop bits (word length = 6, 7, 8)
00 - 5 bits
01 - 6 bits
10 - 7 bits
11 - 8 bits
Quad UART with 64-byte FIFO
© Koninklijke Philips Electronics N.V. 2003. All rights reserved.
SC16C754
24 of 49

Related parts for SC16C754