SY3120 SMC, SY3120 Datasheet - Page 9

no-image

SY3120

Manufacturer Part Number
SY3120
Description
2 position single
Manufacturer
SMC
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SY3120
Manufacturer:
SANY
Quantity:
20 000
Part Number:
SY3120A33M3G
Manufacturer:
SANY
Quantity:
20 000
Part Number:
SY3120A33P3G
Manufacturer:
SANY
Quantity:
20 000
Part Number:
SY3120A50M3G
Manufacturer:
SANY
Quantity:
20 000
Part Number:
SY3120A50P3G
Manufacturer:
SANY
Quantity:
20 000
Response Time
SY3000
SY5000
2 position single
2 position double
3 position
2 position single
2 position double
3 position
actuation
actuation
Type of
Type of
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage)
Made to Order
(For details, refer to pages 324 to 332.)
Without light/surge
voltage suppressor
Without light/surge
voltage suppressor
Response time (ms) (at the pressure of 0.5 MPa)
Response time (ms) (at the pressure of 0.5 MPa)
12 or less
10 or less
15 or less
19 or less
18 or less
32 or less
With light/surge voltage suppressor
With light/surge voltage suppressor
Body Ported
Type S, Z
15 or less
13 or less
20 or less
Type S, Z
26 or less
22 or less
38 or less
Specifications
Solenoid Specifications
Impact/Vibration resistance (m/s
Electrical entry
Coil rated
voltage (V)
Allowable voltage fluctuation
Power
consumption (W)
Apparent power
(VA) ∗
Series
Fluid
Internal pilot
Operating pressure
range (MPa)
Ambient and fluid temperature (°C)
Max. operating
frequency (Hz)
Manual override (Manual operation)
Pilot exhaust method
Lubrication
Mounting orientation
Enclosure
Surge voltage suppressor
Indicator light
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage
Type R, U
Type R, U
12 or less
10 or less
16 or less
19 or less
18 or less
32 or less
∗ Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the
Series
fluctuation range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz.
T type: 24 VDC: –8% to +10%
DC
AC
2 position single
2 position double
3 position
2 position single, double
3 position
12 VDC: –4% to +10%
12 VDC: –6% to +10%
SY3000/5000/7000/9000
DC
AC
Standard
With power saving circuit
SY7000
SY9000
2 position single
2 position double
3 position
2 position single
2 position double
3 position
50 60
[115 V]
[230 V]
right angles to the main valve and armature in both energized and de-
energized states every once for each condition. (Values at the initial period)
Test was performed at both energized and de-energized states in the axial
direction and at the right angles to the main valve and armature. (Values at
the initial period)
100 V
110 V
200 V
220 V
actuation
actuation
Type of
Type of
Hz
2
)
Note)
0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
[0.94 (With indicator light: 0.97)]
[1.42 (With indicator light: 1.46)]
Diode (Varistor is for DIN terminal and Non-polar type.)
0.78 (With indicator light: 0.81)
0.86 (With indicator light: 0.89)
1.18 (With indicator light: 1.22)
1.30 (With indicator light: 1.34)
Without light/surge
Without light/surge
voltage suppressor
voltage suppressor
Push-turn locking slotted type, Push-turn locking lever type
Dust proof (∗ DIN terminal and M8 connector: IP65)
Response time (ms) (at the pressure of 0.5 MPa)
Response time (ms) (at the pressure of 0.5 MPa)
SY3000
31 or less
27 or less
50 or less
35 or less
35 or less
62 or less
Common exhaust type for main and pilot valve
Grommet (G), (H)
L plug connector (L)
M plug connector (M)
G, H, L, M, W
24, 12, 6, 5, 3
LED (AC of DIN connector is neon light.)
10
3
±10% of rated voltage ∗
0.1 (With indicator light only)
–10 to 50 (No freezing.)
Non-locking push type,
SY5000
100, 110, 200, 220
5
3
With light/surge voltage suppressor
With light/surge voltage suppressor
Not required
Unrestricted
0.15 to 0.7
0.1 to 0.7
0.2 to 0.7
Type S, Z
38 or less
30 or less
56 or less
Type S, Z
41 or less
41 or less
64 or less
150/30
Air
[0.94 (With indicator light: 1.07)]
[1.39 (With indicator light: 1.60)]
0.78 (With indicator light: 0.87)
0.86 (With indicator light: 0.97)
1.15 (With indicator light: 1.30)
1.27 (With indicator light: 1.46)
SY7000
DIN terminal (D), (Y)
M8 connector (W)
5
3
24, 12
D, Y
Type R, U
Type R, U
33 or less
28 or less
50 or less
35 or less
35 or less
62 or less
SY9000
5
3
109
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7