In the case of a flat ribbon cable type, each valve is
wired on the print board of manifold base to allow
the external wiring to be piped all together with 26
pins MIL connector.
How to Order Connector Assembly
For 12, 24 VDC
For 100 VAC
For 110 VAC (115 VAC)
• For non-polar (U) valves, the electrical DC
For single solenoid
Double solenoid
3 position
Single
with spacer assembly
Double, 3 position
with spacer assembly
For single solenoid
Double solenoid
3 position
Single
with spacer assembly
Double, 3 position
with spacer assembly
For single solenoid
Double solenoid
3 position
Single
with spacer assembly
Double, 3 position
with spacer assembly
connections can be used with either positive
and negative COM. For type (Z), only use with
positive COM as the valve does not operate
correctly when used with negative COM.
the use of the flat cable connector.
Multiple valve wiring is simplified through
Clean appearance
Specifications
Specifications
Specifications
Caution
SY9000-37-1A
SY9000-37-2A
SY9000-37-3A
SY9000-37-4A
SY9000-37-1B
SY9000-37-2B
SY9000-37-3B
SY9000-37-4B
SY9000-37-1C
SY9000-37-2C
SY9000-37-3C
SY9000-37-4C
For SY9000
For SY9000
For SY9000
Manifold Specifications
Flow Characteristics
Internal Wiring of Manifold (Non-polar type)
SS5Y9-23P(-Q)
Model
Applicable valve
Manifold type
P (SUP)/R (EXH)
Valve stations
A, B port location
Port size
Manifold base mass W (g)
n: Stations
Applicable flat ribbon cable connector
Internal wiring
Rated voltage
Wiring unit
Note)
Terminal no. is not indicated on the connector. The
terminal no. indicated in the connection schematic of
connector, as shown in the reference, means a
correlation of 1, 2, 3····26 from the triangle mark side on
the flat ribbon cable of connector.
Model
Note 1) For more than 10 stations, supply pressure to P port on both sides and exhaust from EA/EB port on both sides.
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or its equivalent.
Note 3) Refer to “Manifold Option” on page 173.
Note 4) CE-compliant: For DC only.
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
• For more than 10 stations, both poles of the common should be wired.
• For single solenoid, connect to the solenoid A side.
• The maximum number of stations that can be accommodated is 12. For more stations, please contact SMC.
Station
P, EA, EB port
A, B port
(P, EA, EB)
Note4)
1, 5, 3
3 8
Port size
Solenoid B side
Solenoid A side
(Max. 12 stations)
Body Ported
Station 12
(A, B)
C12
4, 2
Flat ribbon cable connector, Socket: 26 pins MIL with strain relief, Conforming to MIL-C-83503
In common between +COM and –COM (Z type: +COM only)
C (dm
6.3
3
Station 4
/(s·bar))
1 → 4/2 (P → A/B)
Series
0.20
C10 (One-touch fitting for ø10)
C12 (One-touch fitting for ø12)
Common SUP, Common EXH
b
C8 (One-touch fitting for ø8)
Station 3
12, 24 VDC, 100, 110 VAC
4 to 12 stations
Triangle mark
SS5Y9-23P(-Q)
W = 73n + 259
Stacking type
Flow characteristics
SY9„20
1.5
Cv
Valve
SY9000
3 8
1 4
3 8
Station 2
Reference figure
C (dm
Note1)
8.2
3
4/2 → 5/3 (A/B → EA/EB)
/(s·bar))
Station 1
Triangle mark
Connector
position
0.28
b
Coil
Note)
Type
23P
Cv
1.9
161
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7

Related parts for SY3120