LTC1417 LINER [Linear Technology], LTC1417 Datasheet - Page 22

no-image

LTC1417

Manufacturer Part Number
LTC1417
Description
Low Power 14-Bit, 400ksps Sampling ADC Converter with Serial I/O
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC1417ACGN
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC1417ACGN
Manufacturer:
LTNEAR
Quantity:
20 000
Part Number:
LTC1417ACGN#PBF
Manufacturer:
CYPRESS
Quantity:
120
Part Number:
LTC1417ACGN#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC1417ACGN#TRPBF
Manufacturer:
LT
Quantity:
450
Part Number:
LTC1417AIGN
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC1417AIGN#PBF
Manufacturer:
LT
Quantity:
450
Part Number:
LTC1417CGN
Manufacturer:
LT/凌特
Quantity:
20 000
EXTCLKIN
APPLICATIONS
LTC1417
Using an External Conversion Clock and an External
Data Clock. In Figure 20, data is also output after each
conversion is completed and before the next conversion is
started. An external clock is used for the conversion clock
and either another or the same external clock is used for
the SCLK. This mode is identical to Figure 19 except that
an external clock is used for the conversion. This mode
allows the user to synchronize the A/D conversion to an
external clock either to have precise control of the internal
bit test timing or to provide a precise conversion time. As in
22
CONVST
BUSY
D
SCLK
OUT
RD
t
t
dEXTCLKIN
3
t
2
1
U
2
(SAMPLE N)
3
Figure 20. External Conversion Clock Selected. Data Transferred After Conversion
Using an External SCLK. BUSY Indicates End of Conversion
4
INFORMATION
U
5
HOLD
6
t
CONV
7
CONVST
Hi-Z
8
W
9 10 11 12 13 14 15 16
13
CONVST
U
LTC1417
EXTCLKIN
BUSY
SCLK
D
OUT
RD
t
4
14
9
6
12
7
D13
t
Figure 19, this mode works when the SCLK frequency is
very low (less than 30kHz). However, the external conver-
sion clock must be between 30kHz and 9MHz to maintain
accuracy. If more than 16 SCLKs are provided, more zeros
will be filled in after the data word indefinitely. To select the
external conversion clock, apply an external conversion
clock to EXTCLKIN. The external SCLK is applied to SCLK.
RD can be used to gate the external SCLK such that data will
be clocked out only after RD goes low.
6
1
t
10
t
7
12 11 10 9
2
3
4
SCLK
D
5
OUT
DATA N
8
6
CLKOUT
INT
C0
SCK
MISO
P OR DSP
7
7
t
t
6
V
8
5
9
SAMPLE
D13
IL
5
9 10 11 12 13 14 15 16
t
12
4
t
t
11
LSCLK
3
RISING CLOCK
CAPTURE ON
2
1
0
D12
t
HSCLK
ZEROS
FILL
FALLING CLOCK
CAPTURE ON
t
8
Hi-Z
D11
1
1417 F20
2
V
V
OH
OL
3 4