ST6200 STMICROELECTRONICS [STMicroelectronics], ST6200 Datasheet - Page 55

no-image

ST6200

Manufacturer Part Number
ST6200
Description
8-BIT MCUs WITH A/D CONVERTER, TWO TIMERS, OSCILLATOR SAFEGUARD & SAFE RESET
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST6200
Manufacturer:
ST
0
Part Number:
ST6200/HSP
Manufacturer:
ST
0
Part Number:
ST6200C/MIJ
Manufacturer:
ST
0
Part Number:
ST6200CB1
Manufacturer:
ST
0
Part Number:
ST6200CB1/MML
Manufacturer:
ST
0
Part Number:
ST6200CM6/MSETF
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST6200QNL
Manufacturer:
PULSE10
Quantity:
58
Part Number:
ST6200T
Manufacturer:
ST
Quantity:
20 000
INSTRUCTION SET (Cont’d)
Conditional Branch. Branch instructions perform
a branch in the program when the selected condi-
tion is met.
Bit Manipulation Instructions. These instruc-
tions can handle any bit in Data space memory.
One group either sets or clears. The other group
(see Conditional Branch) performs the bit test
branch operations.
Table 17. Conditional Branch Instructions
Notes
b
e
ee
Table 18. Bit Manipulation Instructions
Notes:
b
rr
Bit Manipulation Instructions should not be used on Port Data Registers and any registers with read only and/or write only bits (see I/O port
chapter)
Table 19. Control Instructions
Notes:
1.
Table 20. Jump & Call Instructions
Notes:
abc 12-bit address
*
JRC e
JRNC e
JRZ e
JRNZ e
JRR b, rr, ee
JRS b, rr, ee
SET b,rr
RES b,rr
NOP
RET
RETI
STOP
WAIT
CALL abc
JP abc
3-bit address
5 bit signed displacement in the range -15 to +16
8 bit signed displacement in the range -126 to +129
3-bit address
Data space register
This instruction is deactivated and a WAIT is automatically executed instead of a STOP if the watchdog function is selected.
Affected
Not Affected
Instruction
Instruction
Instruction
Instruction
:
(1)
C = 1
C = 0
Z = 1
Z = 0
Bit = 0
Bit = 1
Bit Direct
Bit Direct
Inherent
Inherent
Inherent
Inherent
Inherent
Extended
Extended
Addressing Mode
Addressing Mode
Addressing Mode
Branch If
Bytes
Bytes
Bytes
Bytes
2
2
1
1
1
1
3
3
2
2
1
1
1
1
1
rr
*
Control Instructions. Control instructions control
microcontroller operations during program execu-
tion.
Jump and Call. These two instructions are used
to perform long (12-bit) jumps or subroutine calls
to any location in the whole program space.
*
*Not Affected
Affected. The tested bit is shifted into carry.
Not Affected
Data space register
Cycles
Cycles
Cycles
Cycles
Not Affected
4
4
2
2
2
2
5
5
4
4
2
2
2
2
2
ST6200C/ST6201C/ST6203C
Z
Z
Z
Z
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Flags
Flags
Flags
Flags
C
C
C
C
*
*
*
*
*
*
*
*
*
*
*
*
55/100
1

Related parts for ST6200