PLL520-10 PhaseLink (PLL), PLL520-10 Datasheet
PLL520-10
Related parts for PLL520-10
PLL520-10 Summary of contents
Page 1
... Integrated variable capacitors. Supports 3.3V-Power Supply. Available in die form. Thickness 10 mil. DESCRIPTIONS PLL520- VCXO IC specifically designed to pull frequency fundamental crystals from 65MHz to 130MHz, with an integrated Phase Locked Loop for selectable 1x (no PLL), 2x multipliers. Its design was optimized to tolerate higher limits of interelectrodes capacitance and bonding capacitance to improve yield ...
Page 2
... Fremont Blvd., Fremont, California 94538 TEL (510) 492-0990 FAX (510) 492-0991 Pad #19 Pad #20 SEL1 SEL0 1 1 Fin Fin Fin multiplication (no PLL) SYMBOL SYMBOL CONDITIONS CX+ 65MHz to 130 MHz CX- (VDD=3.3V Fund. PLL520-10 Preliminary Selected Multiplier MIN. MAX -0 -0 -65 150 S ...
Page 3
... VCXOSTB XTAL C /C < 350 VCON 3.3V, at room temp. VCON = 0 to 3.3V 0V VCON 3.3V, -3dB SYMBOL CONDITIONS I PECL/LVDS/CMOS 1.4V (CMOS) @ 1.25V (LVDS) @ Vdd – 1.3V (PECL) PLL520-10 Preliminary MIN. TYP. MAX. UNITS 10 ms 200* ppm 100* ppm 4 – 18 10* 65 ppm kHz MIN. TYP. ...
Page 4
... -4mA (Standard drive) OHC OH At TTL level (High drive) At TTL level (Standard drive) SYMBOL CONDITIONS 0.8V ~ 2.0V with 10 pF load 0.3V ~ 3.0V with 15 pF load 0.8V ~ 2.0V with 10 pF load 0.3V ~ 3.0V with 15 pF load PLL520-10 Preliminary MIN. TYP. MAX. 3. 24* 29* 32* 0.5* 1.5* 1.5* @1kHz @10kHz ...
Page 5
... I OSD SYMBOL CONDITIONS R = 100 (see figure LVDS Transistion Time Waveform OUT 0V (Differential) OUT 80 DIFF 20 PLL520-10 Preliminary MIN. TYP. MAX. 247 355 454 -50 50 1.4 1.6 0.9 1.1 1.125 1.2 1.375 -5.7 -8 MIN. TYP. MAX. 0.2 0.7 1.0 0.2 0.7 1.0 LVDS Switching Test Circuit ...
Page 6
... V OL SYMBOL CONDITIONS @20/80% - PECL t r @80/20% - PECL t f PECL Output Skew VDD OUT 2.0V 50% OUT PECL Transistion Time Waveform DUTY CYCLE PLL520-10 Preliminary MIN. MAX. V – 1.025 DD V – 1.620 DD MIN. TYP. MAX. 0.6 1.5 0.5 1.5 t SKEW Rev 4/01/02 Page 6 UNITS V V UNITS ...
Page 7
... PLL520-10 Preliminary Rev 4/01/02 Page 7 ...
Page 8
... LIFE SUPPORT POLICY: PhaseLink’s products are not authorized for use as critical components in life support devices or systems without the express written approval of the President of PhaseLink Corporation. 47745 Fremont Blvd., Fremont, California 94538 TEL (510) 492-0990 FAX (510) 492-0991 47745 Fremont Blvd., Fremont, CA 94538, USA Tel: (510) 492-0990 Fax: (510) 492-0991 PART NUMBER PLL520- PLL520-10 Preliminary TEMPERATURE C=COMMERCIAL M=MILITARY ...