SI2414 SILABS [Silicon Laboratories], SI2414 Datasheet - Page 44

no-image

SI2414

Manufacturer Part Number
SI2414
Description
Manufacturer
SILABS [Silicon Laboratories]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI2414-FT
Manufacturer:
SILICON
Quantity:
50
Part Number:
SI2414-FT
Manufacturer:
SILICONIX
Quantity:
20 000
Part Number:
SI2414-FTR
Manufacturer:
SILICON/PBF
Quantity:
4 250
Part Number:
SI2414-FTR
Manufacturer:
CSR
Quantity:
20 000
Part Number:
SI2414-KT
Quantity:
8
Part Number:
SI2414-KT
Manufacturer:
SHARP
Quantity:
22 030
Part Number:
SI2414-KT
Manufacturer:
SI
Quantity:
20 000
Part Number:
SI2414-KTR
Manufacturer:
KEC
Quantity:
2 908
Si2456/Si2433/Si2414
44
Register
U2E
U3A
U3B
U3C
U3D
U3E
U2F
U30
U31
U32
U33
U34
U35
U37
U38
U39
U3F
U40
U42
Address
0x002E
0x003A
0x003B
0x003C
0x003D
0x003E
0x002F
0x0030
0x0031
0x0032
0x0033
0x0034
0x0035
0x0037
0x0038
0x0039
0x003F
0x0040
0x0042
(Hex)
BMOT
RMOT
DTWD
DMOT
RMTT
Name
BMTT
PDBT
RDLT
BDLT
PD0
PD1
PD2
PD3
PD4
PD5
PD6
PD7
PD8
PD9
Table 21. U-Register Description (Continued)
Description
Busy cadence minimum total time in seconds multiplied by 7200.
Country-specific settings for busy, ringback, and dialtone cadences
are specified by a range for ON time (minimum ON and maximum
ON) and a range for OFF time (minimum OFF and maximum OFF).
The Si2456/33/14 uses three registers to fully specify this range:
MTT, DLT, and MOT. MTT is the minimum total time and is equal to
the minimum ON time plus the minimum OFF time. DLT is the allow-
able delta. This is equal to maximum total time (maximum ON time
plus the maximum OFF time) minus the minimum total time (MTT).
MOT is simply the minimum ON time.
Example: A country specifies a busy tone with ON time from 1–2
seconds and OFF time from 3–4 seconds. Thus, minimum ON time
= 1 sec, maximum ON time = 2 sec, minimum OFF time = 3 sec,
and maximum OFF time = 4 sec. BMTT = 1 + 3 = 4 seconds, maxi-
mum total time = 2 + 4 = 6 seconds, so BDLT = 6 – 4 = 2 seconds,
and BMOT = 1.
Busy cadence delta in seconds multiplied by 7200.
Busy cadence minimum on time in seconds multiplied by 7200.
Ringback cadence minimum total time in seconds multiplied by
7200.
Ringback cadence delta in seconds multiplied by 7200.
Ringback cadence minimum on time in seconds multiplied by 7200.
Window to look for dialtone in seconds multiplied by 1000.
Minimum dialtone on time in seconds multiplied by 7200.
Number of pulses to dial 0.
Number of pulses to dial 1.
Number of pulses to dial 2.
Number of pulses to dial 3.
Number of pulses to dial 4.
Number of pulses to dial 5.
Number of pulses to dial 6.
Number of pulses to dial 7.
Number of pulses to dial 8.
Number of pulses to dial 9.
Pulse dial break time (ms units).
Rev. 0.9
0xEF10
0x003D
Default
0x25F8
0x1B58
0x2D00
0x000A
0x0870
0x0438
0x4650
0x1200
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
0x0007
0x0008
0x0009

Related parts for SI2414