hfct-5612 Avago Technologies, hfct-5612 Datasheet - Page 6

no-image

hfct-5612

Manufacturer Part Number
hfct-5612
Description
Gigabit Interface Converters Gbic For Fibre Channel
Manufacturer
Avago Technologies
Datasheet
Regulatory Compliance
Note: HFBR-5602 is non-compliant for Tx fault timing.
6
Feature
Electrostatic Discharge
(ESD) to the Electrical
Pins
Electrostatic Discharge
(ESD) to the Duplex SC
Receptacle
Electromagnetic Interfer-
ence (EMI)
Immunity
Laser Eye Safety
Component Recognition Underwriters Laboratories and
Test Method
MIL-STD-883C
Method 3015.4
Variation of IEC 801-2
FCC Class B
CENELEC EN55022 Class B (CISPR
22A)
VCCI Class 1
Variation of IEC 801-3
US 21 CFR, Subchapter J per para-
graphs 1002.10 and 1002.12
EN 60825-1: 1994+A11
EN 60825-2: 1994
EN 60950: 1992+A1+A2+A3
Canadian Standards Association
Joint Component Recognition for
Information Technology Equipment
Including Electrical Business Equip-
ment.
Targeted Performance
Class 1 (>2000 V)
Typically withstand at least 15 kV without damage
when port is contacted by a Human Body Model
probe.
Margins are dependent on customer board and
chassis design.
Typically show no measurable effect from a10 V/m
field swept from 27 to 1000 MHz applied to the
transceiver without a chassis enclosure
AEL Class I, FDA/CDRH
AEL Class 1, TUV Rheinland of North America
Class III
UL File E173874 (Pending)
HFBR-5602 Accession No. 9720151-04
HFCT-5612 Accession No. 9521220-16
HFBR-5602 Certificate No. R9771018-7
HFCT-5612 Certificate No. 933/51083 Protection