hi-3111pstf Holt Integrated Circuits, Inc., hi-3111pstf Datasheet - Page 23

no-image

hi-3111pstf

Manufacturer Part Number
hi-3111pstf
Description
Avionics Can Controller With Integrated Transceiver
Manufacturer
Holt Integrated Circuits, Inc.
Datasheet
The ERR register indicates CAN bus status and protocol errors. It is read only. All bits default to 0 at power up and maintain their
current status following reset. Bits 4:0 are reset following a host read.
Bit Name
7
6
5
4
3
2
1
0
ERROR REGISTER: ERR
(Read only)
(Read, SPI Op-code 0xDC)
BUSOFF
TXERRP
RXERRP
BITERR
FRMERR
CRCERR
ACKERR
STUFERR
R/W
R
R
R
R
R
R
R
R
Default Description
0
0
0
0
0
0
0
0
Bus-off status indicator.
This bit is set when TEC > 255. Node is in bus off condition. The bit is reset by HI-3110 when a
successful bus recovery sequence is detected (128 x 11 consecutive recessive bits). d the
FILHIT3:0 bits will reflect this value.
Transmit Error Passive status indicator.
This bit is set when 128
Receive Error Passive status indicator.
This bit is set when 128
Bit Error.
A bit error was detected in a transmitted frame (the bit observed on the bus was opposite to
what was expected).
Form Error.
A Form error was detected in a receive frame.
CRC Error.
A CRC error was detected in a receive frame.
Acknowledgement Error.
An ACK error was detected in a receive frame.
Stuff Error.
A bit stuffing error was detected in a received frame.
HOLT INTEGRATED CIRCUITS
£
£
HI-3110
MSB
7
TEC
REC
23
6
£
£
5
255
255.
4
.
3
2
1
LSB
0

Related parts for hi-3111pstf