INSTRUCTIONS
Instruction op codes are used to read, write and configure the HI-
3585. When
instruction op code into the decoder, starting with the first positive
edge. The op code is fed into the SI pin most significant bit first.
For write instructions, the most significant bit of the data word must
immediately follow the instruction op code and is clocked into its
register on the next rising SCK edge. Data word length varies
depending on word type written: 16-bit writes to Control Register,
32-bit ARINC word writes to transmit FIFO or 256-bit writes to the
label-matching enable/disable table.
For read instructions, the most significant bit of the requested data
word appears at the SO pin after the last op code bit is clocked into
the decoder, at the next falling SCK edge.
instructions, data field bit-length varies with read instruction type.
OP CODE
Hex
0A
0B
0C
0D
0E
00
01
02
03
04
05
06
07
08
09
0F
10
12
11
CS
DATA FIELD
goes low, the next 8 clocks at the SCK pin shift an
N x 32 Bits
256 bits
variable
256 bits
32 bits
16 bits
16 bits
None
None
None
None
8 bits
8 bits
8 bits
8 bits
8 bits
None
None
None
After the 8th op code bit is received
After the 8th op code bit is received
Reset the label at the address specified in the data field
Set
Starting with label FF hex, consecutively set or reset each label in descending order
For example, a Data Field pattern starting with 1011 will set labels FF, FD, and FC
hex and reset label FE hex
Programs a division of the ACLK input. If the divided ACLK frequency is 1 MHz and Control
Register bit CR1 is set, the ARINC receiver and transmitter operate from the divided ACLK clock.
Allowable values for division rate are X1, X2, X4, X8, or XA hex. Any other programmed value
results in no clock. Note: ACLK input frequency and division ratio must yield 1 MHz clock.
Read the next word in the Receive FIFO. If the FIFO is empty, it will read zeros
Dump the Receive FIFO. No framing. If
be zeros.
Read the Status Register
Read the Control Register
Read the ACLK divide value programmed previously using op code 07 hex
Read the Label look-up memory table consecutively starting with address FF hex.
Write up to 32 words into the next empty positions of the Transmit FIFO
No instruction implemented
Write the Control Register
Reset the Transmit FIFO.
Transmission enabled by this instruction only if Control Register bit 13 is zero
After the 8th op code bit is received, perform Master Reset (MR)
No instruction implemented
TABLE 1. DEFINED INSTRUCTION OP CODES
the label at the address specified in the data field
HOLT INTEGRATED CIRCUITS
As with write
HI-3585
After the 8th op code bit is received
3
Table 1 lists all instructions. Instructions that perform a reset or set,
or enable transmission are executed after the last SI bit is received
while
, reset all label selections
, set all the label selections
Example:
CS
SCK
SI
CS
CS
DESCRIPTION
is still low.
held low after last word, the data will
MSB
op code 07hex
one SPI Instruction
, the transmit FIFO will be empty
LSB MSB
data field 02hex
LSB