h5an-4dm Omron Corporation, h5an-4dm Datasheet - Page 8

no-image

h5an-4dm

Manufacturer Part Number
h5an-4dm
Description
Digital Timer
Manufacturer
Omron Corporation
Datasheet
Installation
■ Terminal Arrangement
■ Connections
Power Supply Connection
Connect the required supply voltage to terminals 1 and 2.
Load Connection
Terminals 4, 5, and 6 are for contact output while terminals 12 and
13 are for solid-state output. (Terminal 14 is connected to absorb the
surge if an inductive load is connected.)
The control outputs of both contact type and solid-state type are
simultaneously available.
(Internally
connected)
AC Power Supply
(0 V)
Power supply
For DC power
Terminal 1: −
Terminal 2: +
http://www.ia.omron.com/
External
power
supply
Unused
+12 V
Contact output
DC Power Supply
Do not use unused
terminals for relaying.
Leave them open.
Unused
+12 V
Note: Specifications for 12- to 24-VDC, 48-VDC, and 100-VDC
models are listed separately in this datasheet.
Load Operation
(See note.)
Note: Output transistor ON: Low (0 V)
When a Load Operates with Contact Output
When a Load Operates with Solid-state Output
Note: Connect a diode when using a Power Supply of 12 V or less.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Output transistor OFF: High (12 V)
(See
note.)
H5AN
8

Related parts for h5an-4dm