h5an-4dm Omron Corporation, h5an-4dm Datasheet - Page 2

no-image

h5an-4dm

Manufacturer Part Number
h5an-4dm
Description
Digital Timer
Manufacturer
Omron Corporation
Datasheet
Specifications
■ Ratings
Note: Inrush current was measured within the range shown below.
■ Characteristics
Note: This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature changes. It includes the
Rated supply voltage
Operating voltage range
Power consumption
Resetting system and gate
input
One-shot output time
Control outputs
Power supply for externally
connected components
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
rise time of the power supply, and the operating time of the internal and output circuits.
Peak value
Item
http://www.ia.omron.com/
Measurement
time
H5AN-4D:
H5AN-4DM: 100 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Approx. 10 VA (at 240 VAC, 50 Hz), approx. 5 W (at 24 VDC)
Reset by power-OFF: min. power OFF time: 0.5 s
External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s
0.1 to 1 s (adjustable)
Contact output: SPDT, 3 A at 250 VAC, resistive load (cosφ = 1)
Solid-state output: Open collector, 100 mA max. at 30 VDC max.
12 VDC±10%, 80 mA (permissible ripple: 5% max.)
Time
±0.01% ±0.05 s max. (power OFF start), ±0.005% ±0.03 s max. (reset start) (see note)
100 MΩ min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying metal
parts, between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal parts)
750 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 300 m/s
Malfunction: 100 m/s
Operating:
Storage:
Operating:
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
UL (File No. E41515), CSA (File No. LR22310)
Approx. 360 g
100 to 240 VAC (50/60 Hz),
12 to 24, 48, or 100 VDC (permissible ripple: 20% max.)
12 to 24 VDC (permissible ripple: 20% max.)
–10°C to 55°C
–25°C to 65°C
35% to 85%
100,000 operations min. (3 A at 250 VAC, resistive load)
2
2
(approx. 30G)
(approx. 10G)
H5AN-4D/H5AN-4DM
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
H5AN