ml87v2105 Oki Semiconductor, ml87v2105 Datasheet - Page 31

no-image

ml87v2105

Manufacturer Part Number
ml87v2105
Description
Video Signal Noise Reduction Ic With A Built-in 5.6 Mbit Frame Memory
Manufacturer
Oki Semiconductor
Datasheet
OKI Semiconductor
If 4 continuous codes are detected to be the same and their low frequency differential data absolute values are
equal to or greater than the continuous code motion detection level 1/2(YMS[3:1]), the data is judged to have
much motion, and the 4 continuous code motion flag (YMT4) = 1 is set.
If the absolute value is less than the continuous motion detection level, the data is judged to have little motion,
and the 4 continuous code motion flag (YMT4) = 0 is set.
If 5 continuous codes are detected to be the same and their low frequency differential data absolute values are
equal to or greater than the continuous code motion detection level 1/4 (YMS[3:2]), the data is judged to have
much motion, and the 5 continuous code motion flag (YMT5) = 1 is set.
If the absolute value is less than the continuous motion detection level, the data is judged to have little motion,
and the 5 continuous code motion flag (YMT5)=0 is raised.
From the differential data between fields, including color difference signal motion and noise, the high frequency
component ( HC) is filtered with the LPF, extracting only the low frequency differential data ( LC).
Color difference LPF: F(z) = (1/4)z
The low frequency differential data is assumed to have a large proportion of the motion component, so the
absolute value of that data (| LC|) is compared with the color difference noise convergence level set in
CNS[5:0] to determine the amount of motion.
If the result shows that the differential absolute value is greater than the noise convergence level, the data is
judged to have a lot of motion, and the color difference motion flag (CMT) = 1 is set.
If the differential absolute value is less than the noise convergence level, it is determined that there is not much
motion in the data, and the motion flag (CMT) = 0 is set.
This motion flag is used in adjacent pixel motion compensation.
4 Continuous Code Detection
5 Continuous Code Detection
Color Difference Level Motion Detection
Table F1-3-3 (3) Luminance 4 Continuous Code Motion Detection
Table F1-3-3 (4) Luminance 5 Continuous Code Motion Detection
Table F1-3-3 (5) Color Difference Level Motion Detection
Motion detection condition
Motion detection condition
Motion detection condition
| LY|
| LY| < YMS[3:1]
| LY|
| LY| < YMS[3:2]
| LC| > CNS[5:0]
| LC|
-2
| LC| > 64
| LY| > 8
| LY| > 4
+ (1/2)z
YMS[3:1]
YMS[3:2]
CNS[5:0]
0
+ (1/4)z
2
Motion flag (YMT4)
Motion flag (YMT5)
Motion flag (CMT)
1
1
0
1
1
0
1
1
0
PEDL87V2105-02
ML87V2105
31/103

Related parts for ml87v2105