Parameter
AC SPECIFICATIONS
PMU
FV = force voltage, MV = measure voltage, FI = force current, MI = measure current, FN = force nothing.
Table 7.
Parameter
FORCE VOLTAGE (FV)
Dynamic Performance
Propagation Delay, Load Active On
Propagation Delay, Load Active Off
Propagation Delay Matching
Load Spike
Settling Time to 90%
Current Range A
Current Range B
Current Range C
Current Range D
Current Range E
Force Input Voltage Range at
Force Voltage Uncalibrated
Force Voltage Uncalibrated
Force Voltage Offset Tempco
Force Voltage Gain Tempco
Forced Voltage INL
Force Voltage Compliance vs.
to Load Active Off; 50%, 90%
to Load Active On; 50%, 90%
Output For All Ranges
Accuracy for Range C
Accuracy for All Ranges
for All Ranges
for All Ranges
Current Load
Range A
Range B to Range E
Min
−2.0
−100
±25
±2
±200
±20
±2
−7
Min
Typ
±25
±25
±25
±75
±4
±1
±2
Typ
4.1
11
6.9
156
1.6
Max
+6.0
+100
+7
Max
Rev. 0 | Page 11 of 52
V
Unit
mA
mA
μA
μA
μA
mV
mV
μV/°C
ppm/°C
mV
mV
mV
Unit
ns
ns
ns
mV
ns
Test
Level
D
D
D
D
D
D
P
C
C
C
P
C
C
T
T
T
T
T
Test
Level
C
C
C
C
C
Conditions/Comments
PMU enabled, FV, PE disabled, error measured at calibration
points of 0 V and 5 V
PMU enabled, FV, PE disabled, error measured at calibration
points of 0 V and 5 V; repeat for each PMU current range
Measured at calibration points for each PMU current range
Measured at calibration points for each PMU current range
PMU enabled, FV, Range C, PE disabled, after two-point gain/
offset calibration; measured over output range of −2.0 V to
+6.0 V
PMU enabled, FV, PE disabled, force −2.0 V, measure voltage
while PMU sinking zero- and full-scale current; measure ∆V;
force 6.0 V, measure voltage while PMU sourcing zero- and full-
scale current; measure ∆V; repeat for each PMU current range
B
B
B
B
B
Conditions/Comments
Load active on, unless otherwise noted
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = −1.25 V for IOH; measured from 50%
point of RCVxP − RCVxN to 90% point of final output,
repeat for drive low and high
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = −1.25 V for IOH; measured from 50%
point of RCVxP − RCVxN to 90% point of final output,
repeat for drive low and high
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = −1.25 V for IOH; active on vs. active
off, repeat for drive low and high
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 0 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = −1.25 V for IOH; repeat for drive low
and high
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM= −1.25 V for IOH; measured at 90% of
final value