w25x32a Winbond Electronics Corp America, w25x32a Datasheet - Page 12

no-image

w25x32a

Manufacturer Part Number
w25x32a
Description
32m-bit Serial Flash Memory With 4kb Sectors And Dual Output Spi
Manufacturer
Winbond Electronics Corp America
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
w25x32aFIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
w25x32aVSFIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
W25X32A
11 CONTROL AND STATUS REGISTERS
The Read Status Register instruction can be used to provide status on the availability of the Flash
memory array, if the device is write enabled or disabled, and the state of write protection. The Write
Status Register instruction can be used to configure the devices write protection features. See Figure 3.
11.1 STATUS REGISTER
11.1.1 BUSY
BUSY is a read only bit in the status register (S0) that is set to a 1 state when the device is executing a
Page Program, Sector Erase, Block Erase, Chip Erase or Write Status Register instruction. During this
time the device will ignore further instructions except for the Read Status Register instruction (see t
, t
,
W
PP
t
, t
, and t
in AC Characteristics). When the program, erase or write status register instruction has
SE
BE
CE
completed, the BUSY bit will be cleared to a 0 state indicating the device is ready for further instructions.
11.1.2 Write Enable Latch (WEL)
Write Enable Latch (WEL) is a read only bit in the status register (S1) that is set to a 1 after executing a
Write Enable Instruction. The WEL status bit is cleared to a 0 when the device is write disabled. A write
disable state occurs upon power-up or after any of the following instructions: Write Disable, Page
Program, Sector Erase, Block Erase, Chip Erase and Write Status Register.
11.1.3 Block Protect Bits (BP2, BP1, BP0)
The Block Protect Bits (BP2, BP1, and BP0) are non-volatile read/write bits in the status register (S4, S3,
and S2) that provide Write Protection control and status. Block Protect bits can be set using the Write
Status Register Instruction (see t
in AC characteristics). All, none or a portion of the memory array can
W
be protected from Program and Erase instructions (see Status Register Memory Protection table). The
factory default setting for the Block Protection Bits is 0, none of the array protected. The Block Protect bits
can not be written to if the Status Register Protect (SRP) bit is set to 1 and the Write Protect (/WP) pin is
low.
11.1.4 Top/Bottom Block Protect (TB)
The Top/Bottom bit (TB) controls if the Block Protect Bits (BP2, BP1, BP0) protect from the Top (TB=0) or
the Bottom (TB=1) of the array as shown in the Status Register Memory Protection table. The TB bit is
non-volatile and the factory default setting is TB=0. The TB bit can be set with the Write Status Register
Instruction provided that the Write Enable instruction has been issued. The TB bit can not be written to if
the Status Register Protect (SRP) bit is set to 1 and the Write Protect (/WP) pin is low.
11.1.5 Reserved Bits
Status register bit location S6 is reserved for future use. Current devices will read 0 for this bit location. It
is recommended to mask out the reserved bit when testing the Status Register. Doing this will ensure
compatibility with future devices.