sca3000-e05pwb VTI Hamlin, sca3000-e05pwb Datasheet - Page 36

no-image

sca3000-e05pwb

Manufacturer Part Number
sca3000-e05pwb
Description
Sca3000 Series 3-axis Accelerometer
Manufacturer
VTI Hamlin
Datasheet
8
8.1 Offset
8.1.1
8.1.2
VTI Technologies Oy
www.vti.fi
Data sheet references
Offset calibration error
Offset temperature error
SCA3000's offset will be calibrated in X = 0 g, Y = 0 g, and Z = +1 g (Z measuring axis is parallel to
earth’s gravitation) position, see Figure 20.
Offset calibration error is the difference between the sensor's actual output reading and the nominal
output reading in calibration conditions. Error is calculated by
Equation 2
where Output
output reading [counts], Output is sensor’s nominal output in 0 g position and Sens sensor’s nominal
sensitivity [counts/g].
Offset temperature error is the difference between the sensor's output reading in different
temperatures and the sensor’s calibrated offset value at room temperature. Error is calculated by
Equation 3
where Output
is sensor’s X-axis output reading [counts] in temperature T, Output
[counts] at room temperature RT and Sens sensor’s nominal sensitivity [counts/g]. Sensor is in 0 g
position for every measurement point.
Offset
Offset
Pin #1
Figure 20. SCA3000 offset (0 g) position.
X
X
axisCalibE
axisTempEr
X-axisTempEr@T
X-axisCalibEr
X
r
@
=
T
Output
=
Z-axis in +1 g
position
is sensor’s X-axis calibration error in [mg], Output
Output
Doc.Nr. 8257300A.07
is sensor’s X-axis temperature error in [mg] in temperature T, Output
X
Sens
axis
Y
X
axis
Output
@
T
Sens
Output
1000
Earth’s
gravitation
X
,
axis
@
RT
1000
,
X-axis@T
X-axis
X-axis output reading
is sensor’s X-axis
SCA3000 Series
Rev.A.07
X-axis@T
36/ 43