lsm330dlc STMicroelectronics, lsm330dlc Datasheet - Page 51
lsm330dlc
Manufacturer Part Number
lsm330dlc
Description
Inemo Inertial Module 3d Accelerometer And 3d Gyroscope
Manufacturer
STMicroelectronics
Datasheet
1.LSM330DLC.pdf
(67 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LSM330DLC
Manufacturer:
ST
Quantity:
6 296
Company:
Part Number:
LSM330DLC
Manufacturer:
STMicroelectronics
Quantity:
77
Company:
Part Number:
lsm330dlcTR
Manufacturer:
AD
Quantity:
120
Part Number:
lsm330dlcTR
Manufacturer:
ST
Quantity:
20 000
LSM330DLC
8.18
8.19
CLICK_CFG _A (38h)
Table 51.
Table 52.
CLICK_SRC_A (39h)
Table 53.
Table 54.
--
ZD
ZS
YD
YS
XD
XS
--
IA
DCLICK
SCLICK
Sign
Z
--
IA
Interrupt active. Default value: 0
(0: no interrupt has been generated; 1: one or more interrupts have been generated)
Double CLICK-CLICK enable. Default value: 0 (0:double CLICK-CLICK detection dis-
able, 1: double CLICK-CLICK detection enable)
Single CLICK-CLICK enable. Default value: 0 (0:Single CLICK-CLICK detection dis-
able, 1: single CLICK-CLICK detection enable)
CLICK-CLICK Sign. 0: positive detection, 1: negative detection
Z CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Z High event has occurred)
CLICK_CFG_A register
CLICK_CFG_A description
CLICK_SRC_A register
CLICK_SRC_A description
Enable interrupt double CLICK on Z axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on Z axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK on Y axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on Y axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK on X axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on X axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
ZD
DCLICK
Doc ID 022162 Rev 1
ZS
SCLICK
YD
Sign
YS
Z
Register descriptions
XD
Y
XS
X
51/67