NOTE: Apply lubricating oil or grease on threaded and moving parts to
prevent seizure of these components.
1. Re-install the Easy Tool (refer to Mounting the Easy Tool).
2. Move the INSERT SLIDE to the ENGAGED POSITION so that the
3. With the INSERT SLIDE properly mounted on the SHOULDER OF THE
4. Retract the PROBE by turning the HANDLES on the SPINNER NUT
5. Once the PROBE has cleared the valve, close the valve. If the valve does
6. If there is a bleed valve in place, open it to release pressure in the
7. Move the INSERT SLIDE to the RETRACTED POSITION. (See Figure 2.)
8. Remove the PACKING GLAND from the system.
SHOULDER OF THE PROBE CONNECTOR is held by the INSERT
SLIDE. (See Figure 3.)
CAUTION: CONFIRM THAT THE INSERT SLIDE IS PROPERLY
MOUNTED ON THE PROBE. IMPROPER MOUNTING OF THE EASY
TOOL ON TO THE PROBE COULD RESULT IN UNCONTROLLED
RELEASE OF THE PROBE.
PROBE CONNECTOR, loosen the LOCKING NUT.
counterclockwise until the PROBE has cleared the valve.
not close, make sure the rod has been fully retracted.
PACKING GLAND.
Raise the SPINNER NUT until it clears the PROBE. Unlock the SWING
ARM and remove the Easy Tool.
CAUTION: IF THE PROBE MOVES OUTWARD AS THE SPINNER NUT IS
RAISED, MAKE SURE THE VALVE IS FULLY CLOSED AND THE
PRESSURE IN THE NIPPLE HAS BEEN RELEASED.