LTC3589 Linear Technology, LTC3589 Datasheet - Page 34

no-image

LTC3589

Manufacturer Part Number
LTC3589
Description
8-Output Regulator
Manufacturer
Linear Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC3589ELXE-1
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3589EUH
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3589EUJ#PBF
Manufacturer:
LT
Quantity:
700
Part Number:
LTC3589EUJ#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3589EUJ#TRPBF
Manufacturer:
LT/凌特
Quantity:
20 000
Part Number:
LTC3589EUJ-1#PBF
Manufacturer:
LT
Quantity:
157
Part Number:
LTC3589EUJ-1#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3589EUJ-1#TRPBF
Manufacturer:
LT/凌特
Quantity:
20 000
Part Number:
LTC3589EUJ-2
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3589EUJ-2#PBF
Manufacturer:
LT
Quantity:
388
OPERATION
LTC3589
clock cycle. The LTC3589 pulls down the SDA line during
the write acknowledge clock pulse so that it is a stable
LOW during the HIGH period of this clock pulse.
I
The LTC3589 responds to factory programmed read and
write addresses. The write address is 0x68. The read ad-
dress is 0x69. The LSb of the address byte, known as the
read/write bit, is 0 when writing data to the LTC3589 and
1 when reading from it.
I
The LTC3589 has 14 command registers for control inputs.
They are accessed by the I
writing system.
Each write cycle of the LTC3589 consists of a series of
three or more bytes beginning with the LTC3589 write
address. The second byte is the sub-address of the
command register being written to. The sub-address is
a pointer to the register where the data in the third byte
will be stored. The third byte is the data to be written to
the just-received sub-address. Continue alternating sub-
address and data bytes to write multiple registers in a
single START sequence.
I
The master initiates communication with the LTC3589
with a START condition and the LTC3589’s write address.
If the address matches that of the LTC3589, the LTC3589
returns an acknowledge pulse. The master should then
deliver the sub-address. Again the LTC3589 acknowledges
and the cycle is repeated for the data byte. The data byte is
34
SDA
2
2
2
SCL
C Slave Address
C Sub-Addressed Writing
C Bus Write Operation
START
0
0
1
1
1
2
1
1
3
ADDRESS
0
0
4
1
1
5
0
0
6
0
0
7
2
C port via a sub-addressed
WR
0
8
ACK
9
S7 S6
1
Figure 20. LTC3589 I
2
S5
3
SUB-ADDRESS
S4
4
S3
5
S2 S1 S0
6
7
8
2
C Serial Port Read Pattern
ACK
9
START
transferred to an internal holding latch upon the return of
its acknowledge by the LTC3589. Continue writing sub-ad-
dress and data pairs into the holding latches. Addressing
the LTC3589 is not required for each sub-address and
data pair. If desired a REPEAT-START condition may be
initiated by the master where another device on the I
bus is addressed. The LTC3589 remembers the valid data
it has received. Once all the devices on the I
addressed and sent valid data and a global STOP has been
sent, the LTC3589 will update its command latches with
the data it has received.
I
The LTC3589 I
reading of the I
reading a register, the registers sub-address must be writ-
ten. Send a START condition followed by the LTC3589 write
address followed by the sub-address of the register to be
read. The sub-address is now stored as a pointer to the
register. Send a REPEAT-START condition followed by the
LTC3589 read address. Following the acknowledgment of
its read address the LTC3589 returns one bit of information
for each of the next 8 clock cycles. A STOP condition is
not required for the read operation. The read sub-address
is stored until a new sub-address is written.
Verify the data written to the internal data hold latches prior
to committing date to the command registers by reading
back the data before sending a STOP condition.
Continuously poll a register by repeatedly sending a
START condition followed by the LTC3589 read address,
and then clocking the data out after the read address
acknowledge.
2
C Sub-Addressed Reading
0
0
1
1
1
2
1
1
3
ADDRESS
0
0
4
1
5
1
2
2
C command and status registers. Before
C interface supports random address
0
0
6
0
0
7
RD
1
8
ACK
9
R7 R6
1
2
R5
3
R4
4
www.DataSheet4U.com
DATA
R3
5
R2 R1 R0
6
2
C have been
7
8
ACK
9
3589 F20
3589p
STOP
2
C

Related parts for LTC3589