83C576 Philips Semiconductors, 83C576 Datasheet - Page 21

no-image

83C576

Manufacturer Part Number
83C576
Description
80C51 8-bit microcontroller family 8K/256 OTP/ROM/ 6 channel 10-bit A/D/ 4 comparators/ failure detect circuitry/ watchdog timer
Manufacturer
Philips Semiconductors
Datasheet
Philips Semiconductors
1998 Jun 04
NOTE:
*SMOD0/1 is located at PCON.6, PCON.7
**f
80C51 8-bit microcontroller family
8K/256 OTP/ROM, 6 channel 10-bit A/D, 4 comparators,
failure detect circuitry, watchdog timer
OSC
Symbol
FE
SM0
SM1
SM2
REN
TB8
RB8
Tl
Rl
= oscillator frequency
OSC/2
PRE2
PRE1
PRE0
Bit Addressable
Bit:
Function
Framing Error bit. This bit is set by the receiver when an invalid stop bit is detected. The FE bit is not cleared by valid
frames but should be cleared by software. The SMOD0 bit must be set to enable access to the FE bit.
Serial Port Mode Bit 0, (SMOD0 must = 0 to access bit SM0)
Serial Port Mode Bit 1
SM0
Enables the Automatic Address Recognition feature in Modes 2 or 3. If SM2 = 1 then Rl will not be set unless the
received 9th data bit (RB8) is 1, indicating an address, and the received byte is a Given or Broadcast Address.
In Mode 1, if SM2 = 1 then Rl will not be activated unless a valid stop bit was received, and the received byte is a
Given or Broadcast Address. In Mode 0, SM2 should be 0.
Enables serial reception. Set by software to enable reception. Clear by software to disable reception.
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software as desired.
In modes 2 and 3, the 9th data bit that was received. In Mode 1, if SM2 = 0, RB8 is the stop bit that was received.
In Mode 0, RB8 is not used.
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or at the beginning of the stop bit in the
other modes, in any serial transmission. Must be cleared by software.
Receive interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or halfway through the stop bit time in
the other modes, in any serial reception (except see SM2). Must be cleared by software.
0
0
1
1
SCON Address = 98H
DECODE
(SMOD0/1)*
SM0/FE
7
SM1
0
1
0
1
64
000
001
010
011
100
101
110
111
SM1
Mode
6
64
0
1
2
3
Figure 19. SCON: Serial Port Control Register
128
SM2
5
Description
shift register
8-bit UART
9-bit UART
9-bit UART
2
Figure 18. Watchdog Prescaler
256
REN
4
2
512
Baud Rate**
f
variable
f
variable
OSC
OSC
21
TB8
2
/12
/64 or f
3
1024
OSC
2
RB8
/32
2
2048
2
4096
Tl
1
2
8192
Rl
0
2
Reset Value = 0000 0000B
83C576/87C576
DOWN COUNTER
TO WATCHDOG
Product specification
SU00660
SU00766