74HCT7030N,112 NXP Semiconductors, 74HCT7030N,112 Datasheet - Page 12

IC 9X64 FIFO REGISTER 3ST 28-DIP

74HCT7030N,112

Manufacturer Part Number
74HCT7030N,112
Description
IC 9X64 FIFO REGISTER 3ST 28-DIP
Manufacturer
NXP Semiconductors
Series
74HCTr

Specifications of 74HCT7030N,112

Package / Case
28-DIP (0.600", 15.24mm)
Function
Asynchronous, Synchronous
Memory Size
576 (9 x 64)
Data Rate
33MHz
Voltage - Supply
4.5 V ~ 5.5 V
Mounting Type
Through Hole
Logic Family
HCT
Number Of Circuits
1
Maximum Clock Frequency
36 MHz
High Level Output Current
- 6 mA
Low Level Output Current
6 mA
Supply Voltage (max)
5.5 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (min)
4.5 V
Logic Type
CMOS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Access Time
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-2901-5
933798890112
Philips Semiconductors
AC WAVEFORMS
Shifting in sequence FIFO empty to FIFO full
With FIFO full; SI held HIGH in anticipation of empty location
December 1990
9-bit x 64-word FIFO register; 3-state
(1) HC : V
Fig.6
(1) HC : V
Fig.7
HCT: V
HCT: V
Waveforms showing the SI input to DIR output propagation
delay. The SI pulse width and SI maximum pulse frequency.
Waveforms showing bubble-up delay, SO input to DIR output
and DIR output pulse width.
M
M
M
M
= 50%; V
= 50%; V
= 1.3 V; V
= 1.3 V; V
I
I
I
I
= GND to V
= GND to V
= GND to 3 V.
= GND to 3 V.
CC
CC
.
.
12
Notes to Fig.6
1. DIR initially HIGH; FIFO is
2. SI set HIGH; data loaded into
3. DIR drops LOW, input stage
4. SI set LOW; data from first
5. DIR goes HIGH, status flag
6. Repeat process to load 2nd word
7. DIR remains LOW; with attempt
Notes to Fig.7
1. FIFO is initially full, shift-in is held
2. SO pulse; data in the output
3. DIR HIGH; when empty location
4. DIR returns to LOW; FIFO is full
5. SI brought LOW; necessary to
prepared for valid data.
input stage.
“busy”.
location “ripple through”.
indicates FIFO prepared for
additional data.
through to 64th word into FIFO.
to shift into full FIFO, no data
transfer occurs.
HIGH.
stage is unloaded, “bubble-up
process of empty locations
begins”.
reached input stage, flag
indicates FIFO is prepared for
data input.
again.
complete shift-in process, DIR
remains LOW, because FIFO is
full.
74HC/HCT7030
Product specification

Related parts for 74HCT7030N,112