XR16L570 Exar Corporation, XR16L570 Datasheet - Page 28

no-image

XR16L570

Manufacturer Part Number
XR16L570
Description
SMALLEST 1.62V TO 5.5V UART
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L570IL24-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Part Number:
XR16L570IL32-F
Manufacturer:
CYPRESS
Quantity:
101
Part Number:
XR16L570IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
XR16L570IL32-F
Quantity:
55 230
Company:
Part Number:
XR16L570IL32-F
Quantity:
55 230
Company:
Part Number:
XR16L570IL32TR-F
Quantity:
6 000
XR16L570
SMALLEST 1.62V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE
MCR[5]: Xon-Any Enable
MCR[6]: Infrared Encoder/Decoder Enable
MCR[7]: BRG Clock Prescaler Select
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Flag
LSR[3]: Receive Data Framing Error Flag
LSR[4]: Receive Break Flag
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
4.9
Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default).
Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and
the L570 is programmed to use the Xon/Xoff flow control.
Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be a logic 0 during idle data conditions.
Logic 0 = Divide by one. The input clock from the external clock is fed directly to the Programmable Baud
Rate Generator without further modification, i.e., divide by one (default).
Logic 1 = Divide by four. The prescaler divides the input clock from the external clock by four and feeds it to
the Programmable Baud Rate Generator, hence, data rates get reduced 4 times.
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was a logic 0 for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX
input returns to the idle condition, “mark” or logic 1.
Line Status Register (LSR) - Read Only
28
xr
REV. 1.0.0

Related parts for XR16L570