MAX194 Maxim, MAX194 Datasheet - Page 23

no-image

MAX194

Manufacturer Part Number
MAX194
Description
14-Bit / 85ksps ADC with 10A Shutdown
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1940EEE
Manufacturer:
MAXIM
Quantity:
5
Part Number:
MAX1940EEE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1942MDE
Manufacturer:
a
Quantity:
1
Part Number:
MAX1945EUI
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1945REUI
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1945REUI+
Manufacturer:
SIPEX
Quantity:
21 400
Part Number:
MAX1945SEUI
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1945SEUI+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
MAX1946ETA+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1946ETA-T
Manufacturer:
MAXIM
Quantity:
8 000
Part Number:
MAX1946TA
Manufacturer:
DSP
Quantity:
860
Company:
Part Number:
MAX1947ETA33+T
Quantity:
1 284
measure of the ADC’s usefulness. Figure 26 shows the
effective number of bits as a function of the MAX194’s
input frequency calculated from the SINAD.
Figure 24. Circuit to Stop Free-Running Asynchronous CLK
Figure 25. MAX194 FFT Plot
(CLOCK SHUTDOWN)
-110
-130
-150
-10
-30
-50
-70
-90
0
(2 x CLK)
(CLK)
5
CK
Q
J
14-Bit, 85ksps ADC with 10µA Shutdown
______________________________________________________________________________________
10
CLOCK SHUTDOWN
15
FREQUENCY (kHz)
20
+5V
2 x CLK
25
30
J
K
CK
35
f
f
T
IN
S
1 / 2 74HC73
A
= 85kHz
= 1kHz
= +25°C
40
Q
If a pure sine wave is input to an ADC, AC integral non-
linearity (INL) of an ADC’s transfer function results in
harmonics of the input frequency being present in the
sampled output data.
Total Harmonic Distortion (THD) is the ratio of the RMS
sum of all the harmonics (in the frequency band above
DC and below one-half the sample rate, but not includ-
ing the DC component) to the RMS amplitude of the
fundamental frequency. This is expressed as follows:
where V
through V
harmonics. The THD specification in the Electrical
Characteristics includes the 2nd through 5th harmon-
ics. In the MAX194, this distortion is caused primarily
by the changes in on-resistance of the AIN sampling
switches with changing input voltage. These resistance
changes, together with the DAC’s capacitance (which
can also vary with input voltage), cause a varying time
delay for AC signals, which causes significant distortion
at moderately high frequencies (Figure 27).
THD = 20log——————————————
CLK
BP/UP/SHDN
1
MAX194
N
is the fundamental RMS amplitude, and V
are the amplitudes of the 2nd through Nth
(V
2
Total Harmonic Distortion
2
+ V
3
2
+ V
V1
4
2
+ ... + V
N
2
)
23