Description
Specifications: Scope Type: Bench ; Scope Channels: 4 Analogue + 16 Digital + 1 RF ; Bandwidth: 500MHz ; Meter Display Type: XGA TFT-LCD Color ; Sampling Rate: 2.5GSPS ; Input Impedance: 1Mohm ; Rise Time: 700ps ; Input Voltage: 300Vrms ; Supply Volt
Manufacturer
Tektronix
Datasheet
Mixed Domain Oscilloscopes
MDO4000 Series Data Sheet
Features & Benefits
Key Performance Specifications
Mixed Domain Analysis
4 Analog Channels
16 Digital Channels
1 RF Channel
Standard Passive Voltage Probes 3.9 pF Capacitive Loading and
500 MHz or 1 GHz Analog Bandwidth
Time-correlated Analog, Digital, and RF Signal Acquisitions in a Single
Instrument
Wave Inspector
Data from both the Time and Frequency Domains
Amplitude, Frequency, and Phase vs. Time Waveforms derived from
RF Input
Selectable Spectrum Time to Discover and Analyze how RF Spectrum
Changes over Time – Even on a Stopped Acquisition
500 MHz or 1 GHz Bandwidth Models
MagniVu™ High-speed Acquisition provides 60.6 ps Fine Timing
Resolution
50 kHz - 3 GHz or 50 kHz - 6 GHz Frequency Range Models
Ultra-wide Capture Bandwidth ≥1 GHz
®
Controls provide Easy Navigation of Time-correlated
Spectral Analysis
Ease of Use Features
Connectivity
Optional Serial Triggering and Analysis
Optional Application Support
Dedicated Front-panel Controls for Commonly Performed Tasks
Automated Peak Markers Identify Frequency and Amplitude of Spectrum
Peaks
Manual Markers enable Non-peak Measurements
Trace Types Include: Normal, Average, Max Hold, and Min Hold
Detection Types Include: +Peak, –Peak, Average, and Sample
Spectrogram Display enables Easy Observation and Insight into Slowly
Changing RF Phenomena
Automated Measurements Include: Channel Power, Adjacent Channel
Power Ratio (ACPR), and Occupied Bandwidth (OBW)
Trigger on RF Power Level
Triggered or Free Run Spectral Analysis
10.4 in. (264 mm) Bright XGA Color Display
Small Footprint and Lightweight – Only 5.8 in. (147 mm) Deep and 11 lb.
(5 kg)
Two USB 2.0 Host Ports on the Front Panel and Two on the Rear Panel
for Quick and Easy Data Storage, Printing, and Connecting a USB
Keyboard
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or
Direct Printing to a PictBridge
Integrated 10/100/1000BASE-T Ethernet Port for Network Connection
and Video Out Port to Export the Oscilloscope Display to a Monitor or
Projector
Serial Protocol Trigger, Decode, and Search for I
CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and
I
Advanced RF Triggering
Power Analysis
Limit and Mask Testing
HDTV and Custom Video Analysis
2
S/LJ/RJ/TDM
®
-compatible Printer
2
C, SPI, USB, Ethernet,

Related parts for MDO4054-3GSA

MDO4054-3GSA Summary of contents

Page 1

Mixed Domain Oscilloscopes MDO4000 Series Data Sheet Features & Benefits Key Performance Specifications 4 Analog Channels 500 MHz or 1 GHz Bandwidth Models 16 Digital Channels MagniVu™ High-speed Acquisition provides 60.6 ps Fine Timing Resolution 1 RF Channel 50 kHz ...

Page 2

... And this can be done while the oscilloscope is live and running stopped acquisition. 2 www.tektronix.com The upper half of the MDO4000 Series display shows the Time Domain view of the analog and digital channels, while the lower half shows the Frequency Domain view of the RF channel. The orange bar – ...

Page 3

... Figure 3 – Spectrum Time is moved another 120 µs to the right. At this point the spectrum shows that the VCO/PLL has actually overshot the correct frequency and gone all the way to 2.4164 GHz. Figure 4 – The VCO/PLL eventually settles on the correct 2.400 GHz frequency about 340 µs after the VCO was enabled. www.tektronix.com 3 ...

Page 4

... Phase – The instantaneous phase of the RF input, relative to the center frequency vs. time 4 www.tektronix.com Each of these traces may be turned on and off independently, and all three may be displayed simultaneously. RF time domain traces make it easy to understand what’s happening with a time-varying RF signal. ...

Page 5

... In addition to frequency and amplitude, manual marker readouts also include noise density and phase noise readouts depending on whether Absolute or Delta readouts are selected. A “Reference Marker to Center” function instantly moves the frequency indicated by the reference marker to center frequency. www.tektronix.com 5 ...

Page 6

... RF input can be set to Free Run. This is useful when the frequency domain data is continuous and unrelated to events occurring in the time domain. 6 www.tektronix.com Spectral display of a bursted communication both into a device through Zigbee at 900 MHz and out of the device through Bluetooth at 2.4 GHz, captured with a single acquisition. Ultra-wide Capture Bandwidth Today’ ...

Page 7

... But with the optional TPA-N-VPI adapter, any active, 50 Ω TekVPI probe can be used with the RF input on the MDO4000 Series. This enables additional flexibility when hunting for noise sources and enables easier spectral analysis by using true signal browsing input. www.tektronix.com 7 ...

Page 8

... Capture – Triggering on a specific transmit data packet going across a SPI bus. A complete set of triggers, including triggers for specific serial packet content, ensures you quickly capture your event of interest ...

Page 9

... For extended analysis, National Instrument's LabVIEW SignalExpress™ Tektronix Edition provides over 200 built-in functions including time and frequency domain analysis, data logging, and customizable reports. www.tektronix.com ...

Page 10

... MHz - 3 GHz +30 dBm to –40 dBm With CF 1 MHz - 3.25 GHz: –35 dB from ref level With CF >3.25 GHz: –15 dB from ref level 10 µs On Time with a minimum settling Off Time of 10 µs <5 ns MDO4054-6 MDO4104-6 500 MHz 1 GHz 2.5 GS/s 5 GS/s 50 kHz - 6 GHz ...

Page 11

... Amplitude vs. Time, Frequency vs. Time, Phase vs. Time +Peak, –Peak, Average, Sample 1-11 peaks identified based on user-adjustable threshold and excursion values Two manual markers indicating frequency, amplitude, noise density, and phase noise Absolute or Delta FFT Windows FFT Window Kaiser Rectangular Hamming Hanning Blackman-Harris Flat-Top MDO4054-6 MDO4104-6 Factor 2.23 0.89 1.30 1.44 1.90 3.77 www.tektronix.com 11 ...

Page 12

... Minimum Detectable ±0.5 V Pulse Width (Typical) Channel-to-Channel ±10 V Skew (Typical) ±5 V Maximum Input Toggle ±5 V Rate NA MDO4054-X MDO4104-X 20M points 8 1,000 s 400 ps to 1,000 s –10 divisions to 5000 s ±125 ns ±5 ppm over any ≥1 ms interval All MDO4000 Models 500 MS resolution) 20M points 16 ...

Page 13

... MΩ Path For 1 mV/div to 4.98 mV/div; 0.75 div from DC to (All models) 50 MHz, increasing to 1.3 div at rated bandwidth 50 Ω Path For ≥5 mV/div; 0.4 div from MHz, (MDO4054-X) increasing to 1 div at rated bandwidth 50 Ω Path 0.4 div from MHz, increasing to 1 div at (MDO4104-X) rated bandwidth ...

Page 14

... Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field, Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors up to 100 Mb/s RS-232/422/485/UART Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error Mb/s (Optional) 14 www.tektronix.com ...

Page 15

... Sources – Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math Types – Vertical, Horizontal Waveform Count, Hits in Box, Peak Hits, Median, Max, Min, Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3 www.tektronix.com 15 ...

Page 16

... Violation Threshold Actions on Test Failure Actions on Test Complete Trigger out pulse, set remote interface SRQ Results Display Software , I , True RMS Crest Factor Software NI LabVIEW SignalExpress Tektronix Edition OpenChoice ® IVI Driver e*Scope ® Web-based Remote Control LXI Class C Web Interface Description ...

Page 17

... Model Description MDO4054-3 Mixed Domain Oscilloscope with (4) 500 MHz analog channels, (16) digital channels, and (1) 3 GHz RF input MDO4054-6 Mixed Domain Oscilloscope with (4) 500 MHz analog channels, (16) digital channels, and (1) 6 GHz RF input MDO4104-3 Mixed Domain Oscilloscope with (4) 1 GHz analog channels, (16) digital channels, and (1) 3 GHz RF input ...

Page 18

... Signal Inputs – Any Ch1 - Ch4, (D0 - D15; single-ending probing only) Recommended Probing – RS-232/UART: Single ended; RS-422/485: Differential 18 www.tektronix.com Module DPO4EMBD DPO4ENET S, LJ, RJ, 2 DPO4USB S, LJ, RJ, TDM: Single ...

Page 19

... Deskew Fixture Warranty Three-year warranty covering all parts and labor, excluding probes. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. passive voltage probe with ® ...

Page 20

... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...

Related keywords