TDC-GPX acam messelectronic gmbh, TDC-GPX Datasheet - Page 18

no-image

TDC-GPX

Manufacturer Part Number
TDC-GPX
Description
Precision Time Interval Measurement
Manufacturer
acam messelectronic gmbh
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDC-GPX
Manufacturer:
AMS
Quantity:
20 000
Part Number:
TDC-GPX
0
Part Number:
TDC-GPX2
Manufacturer:
AMS
Quantity:
20 000
Part Number:
TDC-GPX2
0
Part Number:
TDC-GPX2FLQM
0
Register 3: Adr = 3
0 – 4
5 – 6
7 – 8
9 – 10
11 – 12
13 – 14
15 – 16
17 – 18
19 – 20
21 – 22
23 – 24
25 – 26
27
Register 4: Adr = 4
0 – 7
8
9
10 – 11
12 – 13
14 – 15
16 – 17
18 – 19
20 – 21
22
23
24
25
26
27
Register 5: Adr = 5
0 – 17
18 – 20
21
22
23
24
25
26
27
acam-messelectronic gmbh - Am Hasenbiel 27 - D-76297 Stutensee-Blankenloch - Germany - www.acam.de
MSet
DelT1
DelT2
DelT3
DelT4
DelT5
DelT6
DelT7
DelT8
RaSpeed0
RaSpeed1
RaSpeed2
GTest
StartTimer
Quiet
Mon
RaSpeed3
RaSpeed4
RaSpeed5
RaSpeed6
RaSpeed7
RaSpeed8
MasterReset
PartialReset
AluTrigSoft
EFlagHiZN
MTimerStart
MTimerStop
StartOff1
ServiceMAdj
StopDisStart
StartDisStart
MasterAluTrig
PartialAluTrig
MasterOenTrig
PartialOenTrig
StartRetrig
Setting resolution factors 1 to 31 in M-Mode
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Service bits, set ‘0’
Switches TStart to DStart, TStop1 to DStop1 and TStop2 to
DStop2 (TTL to ECL, testing in G-Mode)
defines repetition rate of internal Start in (N + 1)*Tref
recommended: 5 µs ( (199 + 1) * 25ns )
‘1’ = Switch on Quiet Mode in G-, R- or M-Mode If Quiet is
set to ‘1’, the ALU doesn’t start automatically, but after a
rising edge at pin ALUTrigger or after writing ‘1’ into Bit
‘AluTrigSoft’ (mandatory in M-Mode)
Switch on M-Mode
Pulse-pair timing adjust, typically set ‘0’
Pulse-pair timing adjust, typically set ‘0’
Pulse-pair timing adjust, typically set ‘0’
Pulse-pair timing adjust, typically set ‘0’
Pulse-pair timing adjust, typically set ‘0’
Pulse-pair timing adjust, typically set ‘0’
‘1’ = general reset excluding configuration registers
‘1’ = general reset excluding configuration registers and
Interface FIFO content
Starts ALU in Quiet Mode
‘1’ = EF output pin is driving all the time
‘1’ = the internal MTimer is started with a Start pulse
‘1’ = the internal MTimer is started with a Stop pulse
Stop disable before a Start pulse
Partial reset by Alutrigger pin HIGH (only with no Quiet
Partial reset by OEN pin LOW (only with OEN not used)
programmable internal Start-offset
Service bits, set “0”
Start disable after a Start pulse
Master reset by Alutrigger pin HIGH (only with no Quiet
Mode)
Mode)
Master reset by OEN pin LOW (only with OEN not used)
Start retrigger
18
x
x
x
x
x
x
x
x
I
x
x
x
x
x
I
I
TDC-GPX
G
G
G
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
R
R
R
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
M
M
M
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Related parts for TDC-GPX