MAX9134GHJ+ Maxim Integrated Products, MAX9134GHJ+ Datasheet - Page 12

no-image

MAX9134GHJ+

Manufacturer Part Number
MAX9134GHJ+
Description
IC SW LVDS CROSSBAR 32TQFP-EP
Manufacturer
Maxim Integrated Products
Type
LVDS Crossbar Switchr
Datasheet

Specifications of MAX9134GHJ+

Applications
Digital Video
Mounting Type
Surface Mount
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Programmable, High-Speed, Multiple
Input/Output LVDS Crossbar Switches
Table 3. I
Figure 3. LIN Bus Signal Format
Figure 4. LIN Write and Read Data Frame
The MAX9132/MAX9134/MAX9135 are read using the
devices’ internally stored command bytes as an
address pointer, the same way the stored command
byte is used as an address pointer for a write. The
pointer does not autoincrement after each data byte is
read. Initiate a read by writing the command byte to the
proper slave address (Figure 2), then send the device’s
slave address with the R/W bit set to 1. The slave now
responds with the contents of the requested register
(Figure 2).
12
Open
Open
Open
High
High
High
______________________________________________________________________________________
AS0
Low
Low
Low
2
PIN
C Slave Addresses
Data Format for Reading from the Slave
BREAK
Open
Open
Open
High
High
High
AS1
Low
Low
Low
FROM MASTER
TRANSMITTED
HEADER
DATA 1
0x01
SYNC
WRITE FORMAT
A[7:5]
101
101
101
101
101
101
101
101
101
INDENTIFIER
PROTECTED
DATA 2
0x02
A4
0
0
0
0
0
0
0
0
1
RESPONSE
SPACE
FRAME SLOT
FRAME
DATA 1
A3
DATA 1
0
0
0
0
1
1
1
1
0
0x00
ADDRESS
The LIN interface is a low-speed, low-cost interface used
in slow control signal traffic in automotive applications.
This device is the slave node in the LIN bus cluster and
is designed based on the LIN Rev. 1.3 specification. The
LIN master sends data to the MAX9132/MAX9134/
MAX9135 LSB first, up to a maximum data rate of
20kbps. The LIN slave node waits for the synchronization
pulse, then synchronizes itself to the pulse. The node
must then read the identifier and send/receive data bytes
to the master, setting the error flag register when neces-
sary. The LIN interface uses the same routing function of
the switch control registers (0x01, 0x02) as the I
FROM A MASTER OR SLAVE
DATA 2
DATA 2
0x01
A2
RESPONSE
READ FORMAT
0
0
1
1
0
0
1
1
0
TRANSMITTED
DATA 3
DATA N*
0x02
A1
0
1
0
1
0
1
0
1
0
DATA 4
0xFF
CHECKSUM
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
A0
*N = 2 FOR WRITE
AND 4 FOR READ
FRAME
INTER-
SPACE
LIN Interface
ADDRESS (HEX)
0XAC
0xAA
0xA0
0xA2
0xA4
0xA6
0xA8
0xAE
0xB0
2
C inter-

Related parts for MAX9134GHJ+