62514-1 TE Connectivity, 62514-1 Datasheet - Page 3

62514-1

Manufacturer Part Number
62514-1
Description
Manufacturer
TE Connectivity
Series
187r
Datasheets

Specifications of 62514-1

Product Type
Terminal
Terminal Line
Standard MAG-MATE
Terminal Configuration
Tab
Tab Hole/dimple
Dimple
Termination Method To Wire/cable
IDC Standard
Ru (ul Component Program)
Approved
Proprietary Name
FASTON
Tab Size (mm [in])
4.75 x 0.51 [.187 x .020]
Cavity Size
Size 2
Magnet Wire Range (mm [awg])
0.36 – 0.57 [23 – 27]
Terminal Height (mm [in])
7.62 [0.300]
Stock Thickness (mm [in])
0.51 [0.020]
Stock Thickness, Magnet Wire Side (mm [in])
0.41 [0.016]
Plating Material
Tin
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Strip
|
|
|
3.5.
Therm al shock.
Hum idity/tem perature cycling.
Tem perature life.
Rev D
NOTE
Product Qualification and Requalification Test Sequence
NOTE
Test Description
Shall meet visual requirements, show no physical damage, and meet requirements of additional
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
2.
(a)
(b)
(c)
See paragraph 4.1.A.
Numbers indicate sequence in which tests are performed.
Both poke-in and cavity measurement shall be performed.
Initial exam ination of product
LLCR
Current cycling
Insertion force (c)
Extraction force (c)
Therm al shock
Hum idity/tem perature cycling
Tem perature life
Final exam ination of product
Test or Exam ination
See Note.
See Note.
See Note.
ENVIRONMENTAL
Figure 1 (end)
Requirem ent
Figure 2
Test Sequence (b)
2,6
1
1
5
4
3
7
Test Group (a)
2
1
2
3
EIA-364-32, Test Condition III.
Subject specim ens to 25 cycles
between -65 and 125 C with 30
m inute dwells at tem perature
extrem es and less than 1 m inute
transition tim e between
tem peratures. Measure LLCR
initially and after testing.
EIA-364-31, Method III.
Subject specim ens to 10 cycles (10
days) between 25 and 65 C at 80 to
100% RH. Measure LLCR initially
and after testing.
EIA-364-17, Method A.
Subject specim ens to 118 C for 33
days. Measure LLCR initially and
after testing.
1
2
3
4
3
Procedure
108-2012
3 of 6

Related parts for 62514-1