AD7147A Analog Devices, AD7147A Datasheet - Page 52

no-image

AD7147A

Manufacturer Part Number
AD7147A
Description
Manufacturer
Analog Devices
Datasheet

Specifications of AD7147A

Resolution (bits)
16bit
# Chan
13
Sample Rate
111SPS
Interface
I²C/Ser 2-Wire,Ser,SPI
Analog Input Type
Capacitive
Ain Range
± 8 pF (Delta C)
Adc Architecture
Sigma-Delta
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7147ACPZ
Manufacturer:
ADI
Quantity:
300
Part Number:
AD7147ACPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7147ACPZ-1
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7147ACPZ-1500
Manufacturer:
ADI
Quantity:
5
Part Number:
AD7147ACPZ-1500
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7147ACPZ-1500RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7147ACPZ-500RL7
Manufacturer:
AD
Quantity:
181
Part Number:
AD7147ACPZ-500RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD7147A
Table 36. STAGEx_CONNECTION[12:7] Register Description (x = 0 to 11)
Data Bit
[1:0]
[3:2]
[5:4]
[7:6]
[9:8]
[11:10]
[13:12]
[14]
[15]
1
X = don’t care.
Default
Value
X
X
X
X
X
X
X
X
X
1
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Name
CIN7_CONNECTION_SETUP
CIN8_CONNECTION_SETUP
CIN9_CONNECTION_SETUP
CIN10_CONNECTION_SETUP
CIN11_CONNECTION_SETUP
CIN12_CONNECTION_SETUP
SE_CONNECTION_SETUP
NEG_AFE_OFFSET_DISABLE
POS_AFE_OFFSET_DISABLE
Rev. B | Page 52 of 68
Description
CIN7 connection setup
CIN8 connection setup
CIN9 connection setup
CIN10 connection setup
CIN11 connection setup
CIN12 connection setup
Single-ended measurement connection setup
Negative AFE offset enable control
Positive AFE offset enable control
00 = CIN7 not connected to CDC inputs
01 = CIN7 connected to CDC negative input
10 = CIN7 connected to CDC positive input
11 = CIN7 connected to BIAS (connect unused CINx inputs)
00 = CIN8 not connected to CDC inputs
01 = CIN8 connected to CDC negative input
10 = CIN8 connected to CDC positive input
11 = CIN8 connected to BIAS (connect unused CINx inputs)
00 = CIN9 not connected to CDC inputs
01 = CIN9 connected to CDC negative input
10 = CIN9 connected to CDC positive input
11 = CIN9 connected to BIAS (connect unused CINx inputs)
00 = CIN10 not connected to CDC inputs
01 = CIN10 connected to CDC negative input
10 = CIN10 connected to CDC positive input
11 = CIN10 connected to BIAS (connect unused CINx inputs)
00 = CIN11 not connected to CDC inputs
01 = CIN11 connected to CDC negative input
10 = CIN11 connected to CDC positive input
11 = CIN11 connected to BIAS (connect unused CINx inputs)
00 = CIN12 not connected to CDC inputs
01 = CIN12 connected to CDC negative input
10 = CIN12 connected to CDC positive input
11 = CIN12 connected to BIAS (connect unused CINx inputs)
00 = Do not use
01 = Use when one CINx is connected to CDC positive
input, single-ended measurements only
10 = Use when one CINx is connected to CDC negative
input, single-ended measurements only
11 = Differential connection to CDC
0 = enable
1 = disable
0 = enable
1 = disable

Related parts for AD7147A