AT32UC3A1512AU Atmel Corporation, AT32UC3A1512AU Datasheet - Page 125

no-image

AT32UC3A1512AU

Manufacturer Part Number
AT32UC3A1512AU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A1512AU

Flash (kbytes)
512 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
69
Ext Interrupts
69
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
1
Uart
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A1512AU-AUR
Manufacturer:
Atmel
Quantity:
10 000
9.4.6.6
9.5
9.5.1
9.5.1.1
32002F–03/2010
Program trace
Program trace overview
Watchpoint Trigger
Branch message summary
Table 9-30.
The AVR32 OCD system provides program trace support via the debug port. The program trace
feature implements a Program Flow Change Model in which the program trace is synchronized
at each program flow discontinuity. This occurs at taken indirect branches and exceptions. A
record of taken / not taken direct branches is included so that the complete program flow can be
decoded.
The development tool can then interpolate what transpires between each program trace mes-
sage by correlating information from branch target messaging and static source or object code
files. Self-modifying code cannot be traced with the Program Flow Change Model because the
source code is not static.
The TM[2] bit in the Development Control register must be set to enable program trace.
Five types of branch messages can be generated:
R/W
R/W
R/W
R/W
R/W
R
1. Program Trace, Indirect Branch is transmitted on most subroutine calls, returns, inter-
2. Program Trace Synchronization is transmitted to indicate the current PC after starting
rupts, exceptions, and any situation where the target address of a branch cannot be
determined from the source code. This message contains the instruction count to iden-
tify the branch and the target PC to identify the branch target.
trace or after trace synchronization is lost.
Bit Number
31:29
28:26
25:23
22:20
19:0
WT, Watchpoint Trigger Register
Field Name
PTS
PTE
DTS
DTE
Reserved
Init. Val.
000
000
000
000
-
Description
PTS - Program Trace Start
000 = Trigger disabled
001 = Program watchpoint 0b
010 = Program watchpoint 1a
011 = Program watchpoint 1b
100 = Program watchpoint 2a
101 = Program watchpoint 2b
110 = Data watchpoint 3a
111 = Data watchpoint 3b
PTE - Program Trace End
000 = Trigger disabled
001 <-> 111 Watchpoint selected as for PTS
DTS - Data Trace Start
000 = Trigger disabled
001 <-> 111 Watchpoint selected as for PTS
DTE - Data Trace End
000 = Trigger disabled
001 <-> 111 Watchpoint selected as for PTS
Reserved
AVR32
125

Related parts for AT32UC3A1512AU