DS2155G Maxim Integrated Products, DS2155G Datasheet - Page 5

IC TXRX T1/E1/J1 1-CHIP 100CSBGA

DS2155G

Manufacturer Part Number
DS2155G
Description
IC TXRX T1/E1/J1 1-CHIP 100CSBGA
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of DS2155G

Function
Single-Chip Transceiver
Interface
E1, HDLC, J1, T1
Number Of Circuits
1
Voltage - Supply
3.14 V ~ 3.47 V
Current - Supply
75mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LFBGA
Includes
BERT Generator and Detector, CMI Coder and Decoder, HDLC Controller
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS2155G
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2155G+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2155G+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS2155G+T&R
Manufacturer:
MAXIM
Quantity:
68
Part Number:
DS2155G+T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2155G/T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2155GC2
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2155GN+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS2155GNC2+T&R
Manufacturer:
MAXIM
Quantity:
14
13. E1 HDLC CONTROLLERS ARE NOT TESTED BELOW ROOM TEMPERATURE
14. SOFTWARE HDLC RESET FUNCTION
15. HDLC CRC ERROR
16. CSU FILTERS NOT TESTED BELOW ROOM TEMPERATURE
17. 2.048 OUTPUT SIGNAL IN G.703 OPERATION IS STRONGER THAN SPECIFIED
Description:
When operating in E1 mode, the HDLC controllers may not function properly at temperatures below
room temperature.
Work Around:
Avoid operation at temperatures below room temperature if using the HDLC controllers in E1 mode.
Description:
The soft reset function of the HDLC controllers may not issue a reset if the RHR bit is applied for less
than 1µs.
Work Around:
The RHR bit must be applied for at least 1µs to ensure a reset occurs.
Description:
The receive packet-status informa tion register reports a "101" (packet too short) status when the
controller receives a flag message or six consecutive 1’s in the message body, instead of reporting a
CRC error.
Work Around:
There is no known software work around for this issue.
Description:
The functionality of the output CSU filters is not tested below room temperature due to the long start-
up time required for the circuitry.
Work Around:
10s is normally sufficient time for the CSU filters to start and function properly over the specified
temperature range.
Description:
The output waveform in G.703 operation is not attenuated to the correct signal level.
Work Around:
This is a specification issue. Actual performance in a G.703 application is not impaired.