SI3210M-FT Silicon Laboratories Inc, SI3210M-FT Datasheet - Page 110

no-image

SI3210M-FT

Manufacturer Part Number
SI3210M-FT
Description
IC SLIC/CODEC PROG 1CH 38TSSOP
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheets

Specifications of SI3210M-FT

Function
Subscriber Line Interface Concept (SLIC), CODEC
Interface
PCM, SPI
Number Of Circuits
1
Voltage - Supply
3.3V, 5V
Current - Supply
88mA
Power (watts)
700mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
*
Includes
BORSCHT Functions, DTMF Generation and Decoding, FSK Generation, Pulse Metering Generation, Voice Loopback Test Modes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3210M-FT
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3210M-FTR
Quantity:
1 617
Si3210/Si3211
Register 96. Calibration Control/Status Register 1
Reset settings = 0001_1111
110
Name
Bit
Type
7
6
5
4
3
2
1
0
Bit
Reserved
CALSP
CALIL
Name
CALR
CALD
CALC
CALT
CAL
D7
Read returns zero.
Calibration Control/Status Bit.
Setting this bit begins calibration of the entire system.
0 = Normal operation or calibration complete.
1 = Calibration in progress.
Calibration Speedup.
Setting this bit shortens the time allotted for V
calibration cycle.
0 = 300 ms
1 = 30 ms
RING Gain Mismatch Calibration.
For use with discrete solution only. When using the Si3201, consult “AN35: Si321x
User’s Quick Reference Guide” and follow instructions for manual calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
TIP Gain Mismatch Calibration.
For use with discrete solution only. When using the Si3201, consult “AN35: Si321x
User’s Quick Reference Guide” and follow instructions for manual calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Differential DAC Gain Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Common Mode DAC Gain Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
I
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
LIM
CAL
R/W
D6
Calibration.
CALSP
R/W
D5
CALR
Rev. 1.45
R/W
D4
Function
CALT
R/W
D3
BAT
settling at the beginning of the
CALD
R/W
D2
CALC
R/W
D1
CALIL
R/W
D0

Related parts for SI3210M-FT