ES-FL-2A BANNER ENGINEERING, ES-FL-2A Datasheet - Page 8

20H6269

ES-FL-2A

Manufacturer Part Number
ES-FL-2A
Description
20H6269
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of ES-FL-2A

Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
4A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
DPDT-NC
No. Of Poles
2
E-Stop Safety Relay
Figure 4. E-Stop Enclosure Dimensions
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Response Time
Input Requirements
Status Indicators
Housing
Mounting
Vibration Resistance
Operating Temperature
Dimensions
Certifications
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441
Tab (Supplied)
DIN Mounting
24V ac/dc ±15% at 250mA maximum; 10% maximum ripple for dc operation
Protected against transient voltages and reverse polarity (dc hookup is without regard to polarity)
Outputs (K1 and K2): two redundant (i. e. total of four) safety relay (forced-guided) contacts
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across
load. Never install suppressors across output contacts (see Warning on page 5).
Auxiliary Monitor Output (K3): One non-safety relay contact
25 milliseconds maximum
Emergency stop switch must have two normally closed contacts each capable of switching 40 to 100mA
@ 12 to 18V dc.
Reset switch must have one normally open contact capable of switching 40 to 100mA @ 12 to 18V dc.
3 green LED indicators:
Power ON
K1 energized
K2 energized
Polycarbonate. Rated NEMA 1 (IEC IP20)
Mounts to standard 35 mm DIN rail track. Relay safety relay must be installed inside an enclosure rated NEMA 3
(IEC IP54), or better.
10 to 55Hz @ .35mm displacement per IEC 68-2-6
0 to 50°C ( 32 to 122°F)
See diagram, below
LISTED
R R
Emergency
Stop
Devices
29YL
DIN Mounting Slot
35.0 mm
(1.38 in)
Contact ratings:
Maximum voltage: 250V ac or 250V dc
Maximum current: 4A ac or dc (resistive load)
Maximum power: 1000VA, 20 watts
Mechanical life: 10,000,000 operations
Electrical life: 100,000 at full resistive load
0630
Product Specifications
Maximum switching voltage: 125V ac or V dc
Maximum switching current: 500 mA (resistive load)
45.0 mm
(1.77 in)
Telephone: (612) 544-3164
110.0 mm
(4.33 in)
FAX (applications) (612) 544-3573
75.0 mm
(2.95 in)

Related parts for ES-FL-2A