Specifications of IS42S32200B-6T

Organization
2Mx32
Density
64Mb
Address Bus
13b
Access Time (max)
6ns
Maximum Clock Rate
166MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-II
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
185mA
Pin Count
86
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S32200B-6T
Manufacturer:
ISSI
Quantity:
39
Part Number:
IS42S32200B-6T
Manufacturer:
ISSI
Quantity:
798
Part Number:
IS42S32200B-6T
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
IS42S32200B-6TL
Manufacturer:
ISSI
Quantity:
6 100
Part Number:
IS42S32200B-6TL
Manufacturer:
ISSI
Quantity:
6 100
Part Number:
IS42S32200B-6TL
Manufacturer:
ISSI
Quantity:
6 960
Part Number:
IS42S32200B-6TL
Manufacturer:
ST
0
IS42S32200B
CAS Latency
Integrated Silicon Solution, Inc. — www.issi.com —
R e v . 0 0 C
09/29/03
same bank. The PRECHARGE command should be issued
x cycles before the clock edge at which the last desired
data element is valid, where x equals the CAS latency
minus one. This is shown in the READ to PRECHARGE
diagram for each possible CAS latency; data element n +
3 is either the last of a burst of four or the last desired of a
longer burst. Following the PRECHARGE command, a
subsequent command to the same bank cannot be issued
until t
hidden during the access of the last data element(s).
In the case of a fixed-length burst being executed to
completion, a PRECHARGE command issued at the
optimum time (as described above) provides the same
operation that would result from the same fixed-length
burst with auto precharge. The disadvantage of the
RP
is met. Note that part of the row precharge time is
COMMAND
COMMAND
CLK
CLK
DQ
DQ
READ
READ
T0
T0
CAS Latency - 2
NOP
NOP
CAS Latency - 3
T1
T1
t
LZ
t
AC
1-800-379-4774
PRECHARGE command is that it requires that the com-
mand and address buses be available at the appropriate
time to issue the command; the advantage of the
PRECHARGE command is that it can be used to truncate
fixed-length or full-page bursts.
Full-page READ bursts can be truncated with the BURST
TERMINATE command, and fixed-length READ bursts
may be truncated with a BURST TERMINATE command,
provided that auto precharge was not activated. The
BURST TERMINATE command should be issued x cycles
before the clock edge at which the last desired data
element is valid, where x equals the CAS latency minus
one. This is shown in the READ Burst Termination
diagram for each possible CAS latency; data element n +
3 is the last desired data element of a longer burst.
NOP
NOP
T2
T2
D
OUT
t
t
OH
LZ
t
AC
NOP
T3
T3
D
DON'T CARE
UNDEFINED
OUT
t
OH
T4
ISSI
17
®