S29GL064A90TFIR4 Spansion Inc., S29GL064A90TFIR4 Datasheet - Page 61

no-image

S29GL064A90TFIR4

Manufacturer Part Number
S29GL064A90TFIR4
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of S29GL064A90TFIR4

Cell Type
NOR
Density
64Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
23/22Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
8M/4M
Supply Current
50mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S29GL064A90TFIR4
Manufacturer:
SHARP
Quantity:
5 600
Part Number:
S29GL064A90TFIR4
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
S29GL064A90TFIR4
Manufacturer:
SPANSION
Quantity:
20 000
Company:
Part Number:
S29GL064A90TFIR4
Quantity:
1 500
Part Number:
S29GL064A90TFIR40
Quantity:
5 530
Part Number:
S29GL064A90TFIR40
Manufacturer:
SPANSION
Quantity:
4 000
Part Number:
S29GL064A90TFIR40
Manufacturer:
SPANAION
Quantity:
1 000
Part Number:
S29GL064A90TFIR40
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
S29GL064A90TFIR40
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Company:
Part Number:
S29GL064A90TFIR40
Quantity:
122
Part Number:
S29GL064A90TFIR40H
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
S29GL064A90TFIR40H
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
S29GL064A90TFIR40H
Manufacturer:
SPANSIO
Quantity:
20 000
10.2
May 21, 2008 S29GL-A_00_A12
Legend
X = Don’t care
RA = Read Address of memory location to be read.
RD = Read Data read from location RA during read operation.
PA = Program Address. Addresses latch on falling edge of WE# or CE# pulse,
whichever happens later.
PD = Program Data for location PA. Data latches on rising edge of WE# or CE#
pulse, whichever happens first.
Notes
1. See
2. All values are in hexadecimal.
3. Shaded cells indicate read cycles. All others are write cycles.
4. During unlock and command cycles, when lower address bits are 555 or
5. No unlock or command cycles required when device is in read mode.
6. Reset command is required to return to read mode (or to erase-suspend-
7. Fourth cycle of the autoselect command sequence is a read cycle. Data bits
8. For S29GL064A and S29GL032A, Device ID must be read in three cycles.
9. For S29GL016A, Device ID must be read in one cycle.
Read
Reset
Enter Secured Silicon Sector Region
Exit Secured Silicon Sector Region
Program
Write to Buffer
Program Buffer to Flash
Write to Buffer Abort Reset
Unlock Bypass
Unlock Bypass Program
Unlock Bypass Reset
Chip Erase
Sector Erase
Program/Erase Suspend
Program/Erase Resume
CFI Query
2AA as shown in table, address bits above A11 and data bits above DQ7 are
don’t care.
read mode if previously in Erase Suspend) when device is in autoselect
mode, or if DQ5 goes high while device is providing status information.
DQ15–DQ8 are don’t care. Except for RD, PD and WC. See
Command Sequence on page 53
Manufacturer ID
Device ID
Device ID
Secured Silicon Sector Factory Protect
Sector Group Protect Verify
(Note 11)
(Note 5)
(Note 6)
Table 7.1 on page 22
(Note 18)
Command Definitions
(Note 8)
(Note 9)
(Note 12)
Command
Sequence
(Note 1)
(Note 15)
(Note 14)
(Note 17)
(Note 16)
(Note 13)
for description of bus operations.
for more information.
Figure 10.2 Command Definitions (x16 Mode, BYTE# = V
1
1
4
6
4
4
4
3
4
4
3
1
3
3
2
2
6
6
1
1
1
D a t a
XXX
XXX
XXX
XXX
XXX
555
555
555
555
555
555
555
555
555
555
555
555
555
RA
SA
55
First
Autoselect
RD
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
F0
29
A0
90
B0
30
98
S h e e t
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
XXX
2AA
2AA
PA
Second
S29GL-A
PD
55
55
55
55
55
55
55
55
55
55
55
00
55
55
SA = Sector Address of sector to be verified (in autoselect mode) or erased.
Address bits A21–A15 uniquely select any sector.
WBL = Write Buffer Location. Address must be within same write buffer page as
PA.
WC = Word Count. Number of write buffer locations to load minus 1.
10. Refer to
11. Data is 00h for an unprotected sector group and 01h for a protected sector
12. Total number of cycles in command sequence is determined by number of
13. Command sequence resets device for next command after aborted write-to-
14. Unlock Bypass command is required prior to Unlock Bypass Program
15. Unlock Bypass Reset command is required to return to read mode when
16. System may read and program in non-erasing sectors, or enter autoselect
17. Erase Resume command is valid only during Erase Suspend mode.
18. Command is valid when device is ready to read array data or when device is
19. Refer to
factory protect status.
group.
words written to write buffer. Maximum number of cycles in command
sequence is 21, including Program Buffer to Flash command.
buffer operation.
command.
device is in unlock bypass mode.
mode, when in Erase Suspend mode. Erase Suspend command is valid only
during a sector erase operation.
in autoselect mode.
and model number.
555
555
555
555
555
555
555
555
555
555
555
555
SA
Third
Table 7.12 on page 40
Table 7.12 on page
Bus Cycles (Notes 2–5)
A0
F0
90
90
90
90
90
88
90
25
20
80
80
(SA)X02
XXX
X00
X01
X01
X03
555
555
PA
SA
Fourth
40, for individual Device IDs per device density
(Note 18)
(Note 10)
00/01
227E
0001
IH
WC
for data indicating Secured Silicon Sector
PD
AA
AA
00
)
X0E
2AA
2AA
PA
Fifth
(Note 19)
PD
55
55
WBL
X0F
555
SA
Sixth
(Note 19)
PD
10
30
61

Related parts for S29GL064A90TFIR4