M48T18-100MH1 STMicroelectronics, M48T18-100MH1 Datasheet - Page 14

RAM Miscellaneous 8KX8 TIMEKEEP 100NS

M48T18-100MH1

Manufacturer Part Number
M48T18-100MH1
Description
RAM Miscellaneous 8KX8 TIMEKEEP 100NS
Manufacturer
STMicroelectronics
Datasheet

Specifications of M48T18-100MH1

Bus Type
Parallel
Date Format
DW:DM:M:Y
Time Format
HH:MM:SS
User Ram
8KB
Operating Supply Voltage (typ)
5V
Package Type
SOH
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
4.5V
Operating Temperature Classification
Commercial
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Pin Count
28
Mounting
Surface Mount
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M48T18-100MH1
Manufacturer:
ST
0
Part Number:
M48T18-100MH1
Manufacturer:
ST
Quantity:
20 000
Part Number:
M48T18-100MH1E
Manufacturer:
ST
0
Part Number:
M48T18-100MH1TR
Manufacturer:
ST
0
Part Number:
M48T18-100MH1TR
Manufacturer:
ST
Quantity:
20 000
Clock operations
3
3.1
3.2
14/31
Clock operations
Reading the clock
Updates to the TIMEKEEPER
prevent reading data in transition. The BiPORT™ TIMEKEEPER cells in the RAM array are
only data registers and not the actual clock counters, so updating the registers can be halted
without disturbing the clock itself.
Updating is halted when a '1' is written to the READ bit, the seventh bit in the control
register. As long as a '1' remains in that position, updating is halted. After a halt is issued,
the registers reflect the count; that is, the day, date, and the time that were current at the
moment the halt command was issued.
All of the TIMEKEEPER registers are updated simultaneously. A halt will not interrupt an
update in progress. Updating is within a second after the bit is reset to a '0.'
Setting the clock
The eighth bit of the control register is the WRITE bit. Setting the WRITE bit to a '1,' like the
READ bit, halts updates to the TIMEKEEPER registers. The user can then load them with
the correct day, date, and time data in 24-hour BCD format (on
WRITE bit to a '0' then transfers the values of all time registers (1FF9h-1FFFh) to the actual
TIMEKEEPER counters and allows normal operation to resume. The FT bit and the bits
marked as '0' in
operation.
See the application note AN923, “TIMEKEEPER
information on century rollover.
Table 5
must be written to '0' to allow for normal TIMEKEEPER and RAM
®
Doc ID 2411 Rev 10
registers should be halted before clock data is read to
®
rolling Into the 21
M48T08, M48T08Y, M48T18
Table
st
5). Resetting the
century” for

Related parts for M48T18-100MH1