M27C1001-70B1 ST Microelectronics, M27C1001-70B1 Datasheet - Page 10

no-image

M27C1001-70B1

Manufacturer Part Number
M27C1001-70B1
Description
Manufacturer
ST Microelectronics
Datasheet

Specifications of M27C1001-70B1

Density
1Mb
Organization
128Kx8
Bus Type
Parallel
In System Programmable
External
Reprogramming Technique
OTP
Access Time (max)
70ns
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Supply Current
50mA
Package Type
PDIP
Pin Count
32
Mounting
Through Hole
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M27C1001-70B1
Manufacturer:
ST
0
Device description
2.7
2.8
2.9
10/24
Figure 5.
Program Inhibit
Programming of multiple M27C1001s in parallel with different data is also easily
accomplished. Except for E, all like inputs including G of the parallel M27C1001 may be
common. A TTL low level pulse applied to a M27C1001's P input, with E low and V
12.75V, will program that M27C1001. A high level E input inhibits the other M27C1001s from
being programmed.
Program Verify
A verify (read) should be performed on the programmed bits to determine that they were
correctly programmed. The verify is accomplished with E and G at V
12.75V and V
Electronic Signature
The Electronic Signature (ES) mode enables the reading out of a binary code from an
EPROM that will identify its manufacturer and type. This mode is intended for use by
programming equipment to automatically match the device to be programmed with its
corresponding programming algorithm. The ES mode is functional in the 25°C ± 5°C
ambient temperature range that is required when programming the M27C1001. To activate
the ES mode, the programming equipment must force 11.5V to 12.5V on address line A9 of
the M27C1001, with V
device outputs by toggling address line A0 from V
held at V
IL
during Electronic Signature mode.
Programming Flowchart
CC
at 6.25V.
PP
= V
YES
NO
CC
FAIL
= 25
++n
= 5V. Two identifier bytes may then be sequenced from the
V CC = 6.25V, V PP = 12.75V
CHECK ALL BYTES
NO
2nd: V CC = 4.2V
P = 100 s Pulse
1st: V CC = 6V
VERIFY
n = 0
Addr
Last
YES
YES
NO
IL
to V
++ Addr
IH
. All other address lines must be
AI00715C
IL
, P at V
IH
, V
M27C1001
PP
PP
at
at