PVX003A0X3-SRZ Lineage Power, PVX003A0X3-SRZ Datasheet - Page 17

DC/DC Converters & Regulators 3-14.4Vin .6-5.5V 3A Neg Logic SMT Analog

PVX003A0X3-SRZ

Manufacturer Part Number
PVX003A0X3-SRZ
Description
DC/DC Converters & Regulators 3-14.4Vin .6-5.5V 3A Neg Logic SMT Analog
Manufacturer
Lineage Power
Series
PVXr
Datasheet

Specifications of PVX003A0X3-SRZ

Product
Non-Isolated / POL
Input Voltage Range
3 VDC to 14.4 VDC
Number Of Outputs
1
Output Voltage (channel 1)
0.6 VDC to 5.5 VDC
Output Current (channel 1)
3 A
Package / Case Size
12.2 mm x 12.2 mm x 6.25 mm
Output Type
Non-Isolated
Output Voltage
0.6 VDC to 5.5 VDC
Lead Free Status / Rohs Status
 Details
Preliminary Data Sheet
January 19, 2012
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 46. The preferred airflow direction
for the module is in Figure 47.
The thermal reference points, T
specifications are also shown in Figure 47. For reliable
operation the temperatures at these points should not
exceed 120
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 46. Thermal Test Setup.
o
C. The output power of the module should
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
3A Analog Pico DLynx
3 – 14.4Vdc input; 0.6Vdc to 5.5Vdc output; 3A output current
ref
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
used in the
Figure 47. Preferred airflow direction and location
of hot-spot of the module (Tref).
TM
: Non-isolated DC-DC Power Modules
17

Related parts for PVX003A0X3-SRZ